Liquiphant FTL33
12

Technical data

For additional information on the technical data, see the Technical Documentation
TI01148F/00/EN.
12.1

Power supply

Electronic version
3-wire DC-PNP
2-wire AC/DC
12.2

Environment

Ambient temperature range
Storage temperature
Climate class
Operating altitude
Shock resistance
Vibration resistance
Reverse polarity protection
Short-circuit protection
Endress+Hauser
Supply voltage
10 to 30 V DC
20 to 253 V
–40 to +70 °C (–40 to +158 °F), see derating →  40
–40 to +85 °C (–40 to +185 °F)
DIN EN 60068-2-38/IEC 68-2-38: test Z/AD
Up to 2 000 m (6 600 ft) above sea level
a = 300 m/s
2
= 30 g, 3 axes x 2 directions x 3 shocks x 18 ms,
as per test Ea, prEN 60068-2-27:2007
2
a(RMS) = 50 m/s
as per test Fh, EN 60068-2-64:2008
2-wire AC/DC
• AC mode: the device has reverse polarity protection.
• DC mode: in the event of reverse polarity the maximum safety mode is always
detected. Check the wiring and perform a function check before commissioning.
The device is not damaged in the event of reverse polarity.
3-wire DC-PNP
Integrated. In the event of reverse polarity, the device is deactivated automatically.
2-wire AC/DC
During switching the sensor checks whether a load, e.g. relay or contactor, is
present (load check). If an error occurs, the sensor is not damaged.
Smart monitoring: normal operation is resumed once the error is fixed.
3-wire DC-PNP
Overload protection/short-circuit protection at I > 250 mA; the sensor is not
destroyed.
Intelligent monitoring: Testing for overload at intervals of approx. 1.5 s; normal
operation resumes once the overload/short-circuit has been rectified.
Power consumption
< 975 mW
< 850 mW
2
2
, ASD = 1.25 (m/s
)
/Hz, f = 5 to 2 000 Hz, t = 3 x 2 h,
Technical data
Current consumption
< 15 mA
< 3.8 mA
39