Configure Tab
Relay Settings
The relay settings are set here. Select the relay
mode (or disable it) and set your DTMF codes for
controlling the relay.
By default the X-1605 will activate the relay
continuously on outbound calls.
Note: Relay must be set to "Door Strike Mode" to
use DTMF to control the relay.
Setting
Description
Select the mode you would like the relay to operate.
Relay Mode
Disabled
Door Strike Mode
Outbound Call
Inbound/Outbound
Relay Mode
Call
Doorbell
Alarm
Ring
Ring Flash
Enabled or Disabled. When enabled, a buzz will be heard after a valid Door Strike
Door Strike Buzz
Code is dialed. This buzz should match the Door Strike time up to 5 seconds. The
volume of this Door Strike Buzz matches the Speaker volume setting.
Door Strike Code
When this code is dialed, the relay will turn on for the length of the Door Strike Time.
The length of time (in seconds) that the relay will activate for (after Door Strike Code
Door Strike Time
or REX input). 0.5-99 seconds (enter 0 for 0.5 second closure).
When this code is dialed the relay will latch off (1 beep is heard from the X-1605
Off Code
speaker).
When this code is dialed the relay will latch on (2 beeps are heard from the X-1605
On Code
speaker).
NOTE: "Off" and "On" codes are also referred to as latching commands. These can be disabled by deleting them. This will prevent the
relay from being stuck in an open position.
NOTE: In-Band DTMF detection is not supported at this time.
Description
The relay is disabled at all times.
The relay can be controlled with Touch tones received by the X-1605. The Door
Strike Code, Off Code and On Code can be entered during a call. The REX Input
can also be used to control the relay.
The relay will activate while outbound calls from the X-1605 are connected.
The relay will activate when calls to/from the X-1605 are connected.
The relay will activate for the programmable Door Strike Time at the beginning of
an outbound call.
The relay will activate continuously while the X-1605 is registered to a SIP server.
When the SIP/Network Alarm activates the Relay will de-energize.
The relay will activate continuously while the X-1605's extension is ringing, and
the "Loud Ring" feature on the X-1605 is enabled.
The relay will activate in a 500mS on/off pattern while the X-1605's extension is
ringing, and the "Loud Ring" feature on the X-1605 is enabled.