Viking X-1605 Series Product Manual page 15

Ip emergency phones with hd video
Table of Contents

Advertisement

Setting
Description
Enabled/Disabled. When enabled the unit will dial again after a call fails or busy
Redial on Busy
signal is heard. When disabled the unit hangs up after a failed/rejected call.
This setting determines how the LED on the X-1605 will act when idle and during
calls.
LED Mode
Entry Phone
Emergency Phone
LED Mode
Emergency Phone
Outbound Only
Off
This value is how many seconds the X-1605 will try to call the "Numbers". Once a call
Ring Timeout
is answered this timer stops and the Call timer is in control. This only affects
outbound calls from the X-1605.
When the SIP/Network Alarm is active (unit is not registered, or a network error) the
X-1605 will beep 3 times every 30 seconds. The LED on the button will also flash.
Alarm Mute
When Alarm Mute is set to enabled, the LED will still flash but no beeps are produced
for the Alarm.
Configure Tab
Advanced Phone Settings
The advanced phone settings page contains
additional phone features from legacy Viking
products. These settings are used before and
during SIP video calls.
Setting
Description
This setting determines how the speaker on the X-1605 will function.
Speaker Mode
On
LED Mode
Silent Monitor
Off Until
Answered
The Id Number is an In-band or RFC 2833 DTMF string sent to the calling party after
Id Number
a "Q" is dialed. Leave blank to disable this feature.
Description
The LED will remain ON in the idle state, turn off while button is
pressed, blink during dialing, light steady when the call is answered,
then turn OFF momentarily when the call is completed.
The LED will remain OFF in the idle state, blink during dialing, light
steady when the call is connected, then turn OFF when the call is
completed.
On outbound calls, the LED will remain OFF in the idle state, blink
during dialing, light steady when the call is connected, then turn OFF
when the call is completed. On inbound calls, the LED will remain off.
This is useful for silent monitoring on inbound calls.
Stays off when idle and during connected calls. Flashes on boot up,
during dialing, and when the unit has a Network/Registration error.
Description
The speaker is active during inbound and outbound calls.
The speaker is will be muted during inbound and outbound calls.
The speaker will remain off until an outbound SIP call is connected. On
inbound calls the speaker will function normally.
15
Factory Default
Enabled
Emergency Phone
30
Disabled
Factory Default
On
Blank - disabled