Configure Tab
Phone Settings
Speed dial numbers, call/dialing options and
volume levels are set on the Phone Settings
Tab. These settings are used to control how the
device acts during inbound and outbound SIP
calls.
Setting
Description
These are the phone numbers/extensions the X-1605 will dial after pressing the Call
Speed Dial Numbers
button. The numbers are dialed top to bottom in order, once a call is answered the
dialing sequence is ended.
1-6 digits. This code must be entered by a caller before the relay can be controlled.
This only applies to calls inbound to the X-1605. A long access code makes the unit
more secure, but keep in mind it will likely be manually dialed by a caller from their
Access Code
SIP device.
Note: In-band DTMF detection is not supported at this time.
When disabled, the unit will ring (if enabled) or reject the call if both auto answer and
Auto Answer
loud ring are disabled.
Affects outbound calls made by the X-1605. Set to 0 to disable the timer. Resolution
Call Time
is in seconds, 1-999.
When enabled, the unit will emit a loud ring signal from its speaker when its SIP
Loud Ring
extension is ringing. The call button can be pressed to answer the call. The inbound
call time limits the "ring" time.
Ring Volume
Changes the volume of Loud Ringing.
Affects inbound ringing calls made to the X-1605. Set to 0 to disable the timer.
Inbound Call Time
Resolution is in seconds, 1-999.
Speaker Volume
0-99. Changes the level of the audio produced by the X-1605 speaker.
Mic Volume
0-99. Changes the level of the audio from the X-1605 microphone.
Enabled/Disabled. Set this to enable when the X-1605 is calling outside of the
Use Call Progress
building and analog audio detection is required.
The number of times the group of programmed numbers is dialed. 0 = continuous
Lap Counter
dialing. Example: 5 numbers are programmed, Lap Counter is set to 3. The unit will
dial 15 times (3 laps of 5 numbers).
14
Factory Default
n/a
123456
Enabled
180 (3 minutes)
Disabled
6
180 (3 minutes)
6
6
Disabled
7

Advertisement