T3PS Specifications
The specifications apply when the T3PS is powered on for at least
30 minutes.
T3PS250041P, T3PS800011P (360W Models)
Model
Rated Output Voltage
Rated Output Current A
Rated Output Power
Power Ratio
Constant Voltage Mode
*1
Line Regulation
*2
Load Regulation
*3
Ripple and Noise
*4
p-p
*5
r.m.s
Temperature
coefficient
Remote sense
compensation voltage
(single wire)
*6
Rise Time
Rated Load
No Load
*7
Fall Time
Rated Load
No Load
Transient response
*8
time
Constant Current Mode
*1
Line regulation
*9
Load regulation
Ripple and noise
*5
r.m.s
Temperature
coefficient
Unit T3PS250041P
V
250
4.5
W
360
--
3.125
mV 128
mV 130
mV 80
mV 15
ppm
100ppm/°C of rated output voltage, after a 30
/ºC
minute warm-up.
V
1
ms
100
ms
100
ms
150
ms
1200
ms
2
mA 9.5
mA 9.5
mA 10
ppm
200ppm/°C of rated output current, after a 30
/ºC
minute warm-up.
APPENDIX
T3PS800011P
800
1.44
360
3.2
403
405
150
30
150
150
300
2000
6.44
6.44
5