Teledyne HASTINGS 200 Instruction Manual
Hide thumbs Also See for HASTINGS 200:

Advertisement

TELEDYNE HASTINGS
INSTRUCTION MANUAL
HASTINGS POWER
HASTINGS POWER
HASTINGS POWER
HASTINGS POWER
HASTINGS POWER
SUPPL
SUPPL
Y MODEL 200
Y MODEL 200
SUPPL
SUPPL Y MODEL 200
SUPPL
Y MODEL 200
Y MODEL 200
INSTRUMENTS
INSTRUCTION
page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HASTINGS 200 and is the answer not in the manual?

Questions and answers

Summary of Contents for Teledyne HASTINGS 200

  • Page 1: Operating Information Operating Information

    TELEDYNE HASTINGS INSTRUCTION INSTRUMENTS INSTRUCTION MANUAL HASTINGS POWER HASTINGS POWER HASTINGS POWER HASTINGS POWER HASTINGS POWER SUPPL SUPPL Y MODEL 200 Y MODEL 200 SUPPL SUPPL SUPPL Y MODEL 200 Y MODEL 200 Y MODEL 200 page 1...
  • Page 2 Revision C (Document Number 114-102002) ............October 2002 Revision D (Document Number 114-082005) ............August 2005 Visit www.teledyne-hi.com for WEEE disposal guidance. Hastings Instruments reserves the right to change or modify the design of its equipment without any obligation to provide notification of change or intent to change.
  • Page 3: Table Of Contents

    T T T T T able of Contents able of Contents able of Contents able of Contents able of Contents 1 . 0 1 . 0 1 . 0 1 . 0 1 . 0 GENERAL INFORMA GENERAL INFORMA GENERAL INFORMA GENERAL INFORMATION GENERAL INFORMA TION...
  • Page 4 page 4...
  • Page 5: Features

    SECTION 1 General Information The Hastings Model 200 Power Supply is a combination power supply and digital readout moni- tors up to two Hastings Flow Instruments having the model number prefixes of HFM, HFC, ST, FST, CST, or CSH. (NOTE: HFM, ST, and FST Series Flowmeters can provide flow readings only and have no control capabilities).
  • Page 6 Accessories: 1.4.1 1.4.1 Alar Alar 1.4.1 1.4.1 1.4.1 Alar Alarms Alar The Model AL-1J Flow Alarm is available as an attachment suitable for use with any 0-5.00 VDC input signal. Calibrated digital dial precision pots determine the low and high set points as a percent of full scale.
  • Page 7: Inst Inst Installa Inst Alla Allation Tion Tion

    SECTION 2 Installation This section is designed to assist you in getting a new power supply into operation as quickly and easily as possible. Please read the following very thoroughly before attempting to install the instrument. Receiving Inspection: Carefully unpack the Hastings Power Supply and any accessories that arrive with it. Inspect it for any obvious signs of damage due to shipment.
  • Page 8: Electrical Connection

    Figure 2.2 Figure 2.3 Electrical Connection: Ensure that the power switch is turned off. Plug the AC line cord into an acceptable receptacle. Then plug the 15 pin D connector cable, purchased separately from Hastings Instruments, into the top of the flow instrument and into the back of the power supply. When looking at the back panel of the power supply the different channels are numbered from left to right (see Figure 2.2).
  • Page 9 2.6.2 2.6.2 Display Display 2.6.2 2.6.2 2.6.2 Display Display Display The DISPLAY switch, located in the upper right hand corner of the front panel, controls the digital display (refer to Figure 2.3). When the DISPLAY switch is in the FLOW position, the display is monitoring the mass flow rate.
  • Page 10 2.6.6 2.6.6 2.6.6 2.6.6 2.6.6 Slave Controllers Slave Controllers Slave Controllers Slave Controllers Slave Controllers The Model 200 Power Supply can be configured to slave one flow controller to another controller or flowme- ter. This is commonly used to generate gas mixtures when varying flowrates are desired. Either channel can be set up as the master or the slave.
  • Page 11: Range Change

    SECTION 3 Operating Information This section contains instructions to change the configuration of the power supply from the way it was set up at the factory. Range Change: Since the display uses a 3-1/2 digit LCD, the highest number that can be displayed is 1999.
  • Page 12: Switch Change

    3.1.3 3.1.3 3.1.3 3.1.3 3.1.3 Displa Displa Display y y y y Adjustment for Master Sla Displa Displa Adjustment for Master Sla Adjustment for Master Sla Adjustment for Master Sla Adjustment for Master Slav v v v v e e e e e To set the master unit, follow the instructions for adjusting the display in an internal command configuration;...
  • Page 13 3.2.1 Soft Star 3.2.1 Soft Star 3.2.1 Soft Star 3.2.1 Soft Star 3.2.1 Soft Star t t t t t For this change to be effective, there is a jumper inside the HFC cover which must also be moved. See the HFC manual for instructions. To change to the soft start method of valve override, remove the two screws on the top of the back panel and slide the aluminum perforated top cover from the unit.
  • Page 14 3.3 External Command Dipswitch: 3.3 External Command Dipswitch: 3.3 External Command Dipswitch: 3.3 External Command Dipswitch: 3.3 External Command Dipswitch: The Hastings Model 200 Power Supply can be set to accept an external command signal or to generate its own command signal. The command source selector dipswitch changes between the external or the internal source.
  • Page 15: Calibration

    SECTION 4 Calibration This section contains a troubleshooting guide to help locate and repair failed components. This troubleshooting guide is designed as a general reference only and will not cover every possible component failure. It is possible for problems with the flow instruments to appear as a failed power supply and vice versa.
  • Page 16: Troubleshooting Chart

    Troubleshooting Chart: SYMPTOM: Display has no indication regardless of the position of the Channel Selector switch and all TP voltages are 0.0 VDC. ACTION: First, ensure the unit is plugged into an operating source of AC power of the proper voltage for the unit. If so, unplug the instrumentation and remove the fuse from the back of the unit.
  • Page 17: Warranty Policy

    If you then choose not to have the product repaired, a minimum will be charged to cover the processing and inspection. Please consult the factory for your RMA number before returning any product repair. TELEDYNE HASTINGS INSTRUMENTS 804 NEWCOMBE AVENUE HAMPTON, VIRGINIA 23669 U.S.A.
  • Page 18 page 18...
  • Page 19: Wings

    SECTION 7 Diagrams and Drawings Document Document Document Title Title Title ..................Title .................................... Document No ..................Document No Document No..Document No Document Document Title ..................Document No Assembly Diag Assembly Diag ram, ram, Model 200 P Model 200 P Model 200 Po o o o o w w w w w er Supply...