Step 13: Remove compressor
Twist off the three foot-nuts on the
compressor with spanner, as well as the
foot cushions, and then remove the
compressor.
Note: Seal the ends of the discharge pipe
and suction pipe to prevent the moisture
and dust.
Step 14: Remove the reactor
Remove the four (4) screws fixing the
reactor and the middle isolation sheet and
then remove the reactor.