Step 7: Remove electric box assembly
a. Remove the grounding wire screw on
the electric box assembly and then
remove the grounding wire.
b. Disconnect the wiring terminals of
reactor, compressor, high and low
pressure switches, compressor overload
protector, temperature sensor, outdoor
fan motor and four-way valve.
Note: Keep pressing the circlip when
disconnecting
the
wiring
reactor; keep pressing the retainer when
disconnecting other wiring terminals.
c. Remove the wire through the wiring
groove.
Step 8: Remove fan blade, motor and motor support
a. Remove the nuts fixing axial flow blade
with wrench, and then remove the fan
blade.
b. Remove the two (2) screws connecting
motor support and chassis, loosen
damper block and then remove the
motor support.
c. Remove the four (4) screws fixing
motor, and then remove the motor.