Step 11: Remove 4-way valve
Recover all the refrigerant from the
system. Unsolder the pipelines connecting
the compressor and condenser assembly.
Then remove the 4-way valve assembly.
Step 12: Remove suction pipe assembly
Unsolder the brazed joint at the suction
pipe assembly as well as the brazed
joint for connection pipe for compressor
and liquid receiver, and then pull it
upwards to remove it.
70