Standalone Configuration
Set the product in one of the standalone modes to control without a DMX controller.
Never connect a product that is operating in any standalone mode to a DMX string
connected to a DMX controller. Products in standalone mode may transmit DMX signals
that could interfere with the DMX signals from the controller.
Automatic Programs
To run the Intimidator Scan 360 in automatic mode, follow the instructions below:
1. Press <MENU> repeatedly until Run Mode shows on the display.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select Auto.
4. Press <ENTER>.
Sound-Active Mode
To run the Intimidator Scan 360 in sound-active mode, do the following:
1. Press <MENU> repeatedly until Run Mode shows on the display.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select Sound.
4. Press <ENTER>.
Sound Sensitivity
To set the sound sensitivity on the Intimidator Scan 360, follow the instructions below:
1. Press <MENU> repeatedly until Setup shows on the display.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select Sound Sensitivity.
4. Press <ENTER>.
5. Use <UP> or <DOWN> to increase or decrease the sound sensitivity, from 001–100.
6. Press <ENTER>.
The product will only respond to low frequencies of music (bass and drums).
Manual Mode
To operate the Intimidator Scan 360 manually through the menu, do the following:
1. Press <MENU> repeatedly until Run Mode shows on the display.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select Manual.
4. Press <ENTER>.
5. Use <UP> or <DOWN> to select from Pan, Tilt, Color, Gobo, Gobo Rotate, Prism, Focus,
Dimmer, or Strobe.
6. Press <ENTER>.
7. Use <UP> or <DOWN> to increase or decrease the value of the function, from 000–255.
8. Press <ENTER>.
9. Repeat steps 3-6 until the product is set as desired.