Daikin Clima-Flex CLIC STAND ALONE Series Installation, Operation And Maintenance Manual page 37

Air-cooled scroll compressor chiller water generator unit
Table of Contents

Advertisement

Mapping Table
Index Size Acronym
DataType
299
1
Hc16
USINT
300
1
Hc17
USINT
301
1
AI_CfgLim-
USINT
Max_Grp2
302
1
He00
UINT(0..9999)
303
1
He01
UINT(0..9999)
304
1
He02
UINT(0..9999)
305
2
Hd04
STRING[4]
307
2
SEtC
REAL
309
2
SEtH
REAL
311
1
AI_CfgLim-
USINT
Max_Grp1
324
2
C017
REAL
326
2
C018
REAL
328
1
E047
USINT(0..2)
331
2
BMS_PwrReq
REAL
335
2
P000
REAL
337
2
P001
REAL
339
1
P002
UINT(0..999)
340
1
P003
UINT(0..999)
341
1
P004
UINT(0..999)
342
2
P005
REAL
344
2
P006
REAL
346
2
P007
REAL
348
1
P008
UINT(0..999)
349
1
P009
UINT(0..999)
350
2
P010
REAL
352
1
P011
UINT(0..999)
353
1
P012
UINT(0..999)
354
1
P013
UINT(0..999)
355
1
P014
UINT(0..999)
356
1
P015
UINT(0..999)
357
1
P019
USINT(0..101)
358
1
P020
USINT(0..101)
359
2
P021
REAL
361
1
P022
UINT
362
1
P023
UINT
363
2
P024
REAL
365
2
P025
REAL
367
2
P026
REAL
369
2
P027
REAL
371
2
P028
REAL
373
2
P029
REAL
375
2
P030
REAL
377
2
P031
REAL
379
1
P032
UINT
380
1
P033
UINT
382
2
S051
REAL
384
2
S052
REAL
386
40
Ha01
STRING
705
2
E048
REAL
707
2
E049
REAL
709
1
U079
UINT(1..15)
710
1
U080
UINT(3..99)
711
2
F009
REAL
713
2
F010
REAL
715
1
ID_CfgLim-
USINT
Max_Slv
716
2
F012
REAL
718
2
F013
REAL
720
2
F014
REAL
722
2
F015
REAL
724
2
F018
REAL
726
2
F019
REAL
728
2
F021
REAL
730
2
F022
REAL
www.clima-flex.com
Min
Max
Init
R/W
UoM
Value
Value
Value
R/W 0
R/W 0
R/W 8
R/W 1
R/W 0
R/W 1234
R/W 0
R/W 7
CELSIUS
R/W 40
CELSIUS
R/W 8
R/W 65
CELSIUS
R/W 0.2
BAR
R/W 0
PERCENT
R/W -25
CELSIUS
R/W 70
CELSIUS
R/W 15
SECOND
R/W 120
SECOND
R/W 60
SECOND
R/W 35
RPS
R/W 35
PERCENT
R/W 35
RPS
R/W 15
MINUTE
R/W 3
MINUTE
R/W 50
RPS
R/W 30
SECOND
R/W 3
SECOND
R/W 1
MINUTE
R/W 20
MINUTE
R/W 20
MINUTE
R/W 0
PERCENT
R/W 0
PERCENT
R/W 0
KILOPASCAL P021 - Max permitted Delta P to start up
R/W 0
SECOND
R/W 0
PERCENT
R/W 0
RPS
R/W 0
RPS
R/W 0
RPS
R/W 45
PERCENT
R/W 90
PERCENT
R/W 30
PERCENT
R/W 0
R/W 0
R/W 0
R/W 0
R/W 80
RPS
R/W 40
RPS
R/W 0
R/W 1
DELTAKELVIN E048 - RESERVED, Delta evap. temp. (Smart opening ExV)
R/W 0.2
DELTAKELVIN E049 - RESERVED, Delta suction temp. (Smart opening ExV)
R/W 3
MINUTE
R/W 15
MINUTE
R/W 14
CELSIUS
R/W 4
DELTAKELVIN F010 - Delivery limit proportional band
R/W 0
R/W 1
DELTAKELVIN F012 - Heater off set in cool
R/W 0.5
DELTAKELVIN F013 - Heater diff erential in cool
R/W 3
DELTAKELVIN F014 - Heater off set in heat
R/W 1
DELTAKELVIN F015 - Heater diff erential in heat
R/W 40
CELSIUS
R/W 5
DELTAKELVIN F019 - Hot-Keep diff erential
R/W 0
DELTAKELVIN F021 - Common delivery user water temp. probe off set
R/W 0
DELTAKELVIN F022 - Evap.2 frost temp. probe off set
37
Description
Hc16 - Digital input 1 confi g. on Secondary board (0=Not
used, 1=User fl ow switch, 2=Comp.1 circ.2 overload,
3=Comp.2 circ.2 overload, 4=Remote ON/OFF, 5=Cool/Heat,
6=2nd set point, 7=Remote alarm, 8=User pump 1 overload,
9=LP pressure switch, 10=User pump 2 overload, 11=Remote
cmd 3, 12=Remote cmd 4, 13=Source alarm)
Hc17 - Digital input confi g. on Secondary board (0=Not used,
1=User fl ow switch, 2=Comp.1 circ.2 overload, 3=Comp.2
circ.2 overload, 4=Remote ON/OFF, 5=Cool/Heat, 6=2nd
set point, 7=Remote alarm, 8=User pump 1 overload, 9=LP
pressure switch, 10=User pump 2 overload, 11=Remote cmd
3, 12=Remote cmd 4, 13=Source alarm)
AI_CfgLimMax_Grp2 - Lim max probe group 2
He00 - USER profi le password
He01 - SERVICE profi le password
He02 - MANUFACTURER profi le password
Hd04 - NFC password
SEtC - Cool set point
SEtH - Heat set point
AI_CfgLimMax_Grp1 - Lim max probe group 1
C017 - Threshold of max high pressure (HP)
C018 - Threshold of min low pressure (LP)
E047 - Type of ExV driver (0= Disabled, 1= EVD embedded,
2=EVD EVO)
Capacity request using BMS net
P000 - Evaporating min temp. custom envelope limit
P001 - Condensing max temp. custom envelope limit
P002 - Prevent min duration
P003 - Out of envelope alarm delay time
P004 - Low pressure diff erence alarm delay
P005 - Circuit destabilisation min BLDC speed threshold
P006 - Oil recovery min request for activation
P007 - Oil recovery min comp. speed for activation
P008 - Oil recovery time before activation in which the comp.
can run at min speed
P009 - Oil recovery duration in which the comp. speed is
forced
P010 - Oil recovery comp. speed in which the comp. is forced
P011- Oil equalisation startup time for solenoid valve on
comp. starts
P012 - Oil equalisation solenoid valve open time
P013 - Oil equalisation solenoid valve min off time
P014 - Oil equalisation solenoid valve max off time
P015 - Oil equalisation max time for management
P019 - Compressor 1 circuit 1 manual mode (0=AUTO, 1=0%,
... 101=100%)
P020 - Compressor 1 circuit 2 manual mode (0=AUTO, 1=0%,
... 101=100%)
P022 - Max EVD pre-opening time to equalise pressure
P023 - EVD pre-opening in case of pre-start to equalise
pressure
P024 - Start-up speed
P025 - Max custom speed (rps)
P026 - Min custom speed (rps)
P027 - BLDC speed request threshold % to call on
P028 - BLDC speed threshold to call on fi xed speed compres-
sor
P029 - BLDC speed threshold to switch off fi xed speed
compressor
P030 - Skip frequency: set 1 [010]
P031 - Skip frequency: band 1 [011]
P032 - Enable motor overtemperature alarm (PTC) (0=OFF,
1=ON) [027]
P033 - Motor overtemperature alarm delay [028]
S051 - BLDC defrost speed
S052 - BLDC cycle reverse speed in defrost
New time zone to set for the controller's internal clock
U079 - Burst funct. time for unit pump on
U080 - Burst funct. time for unit pump off
F009 - Delivery air min. temp. threshold
ID_CfgLimMax_Slv - Lim digital input
F018 - Hot-Start set point
iom-clicsa-cf-eng