Magnet Compass Setting - JRC JMA-5312-6HS Installation Manual

Marine radar equipment
Hide thumbs Also See for JMA-5312-6HS:
Table of Contents

Advertisement

[II] Transmission Monitor Adjustment (MON Indicator Adjustment)
Adjust the circuit for monitoring the transmission performance of the radar equipment.
Note:
The radar system is equipped with an interswitch.
For adjusting the performance unit, set the interswitch connection to straight, i.e. No.1 scanner is
connected to No.1 display unit as the Master.
Procedures
1. Open the Serviceman Menu.
2. Perform the following menu open procedure to open the performance
monitor Indicator Adjustment menu.
3. Increase or decrease the adjustment value so that the performance
monitor level indicator will be adjusted to "8."
4. Press the Exit button to close the adjustment menu.
Note:
During performance monitor adjustment, all acquisitions by the target tracking function are released.
The released target acquisitions are not recovered.
4.18

MAGNET COMPASS SETTING

Set the correction value, when the radar receive HDM sentence from magnet compass or the variation of HDG is
NULL.
Procedures
1. Press the [RADAR MENU] key twice.
2
Open the MAG Compass Setting menu by performing the following
menu operation.
2. Press the [1] key.
The Heading Correction function can be turned on / off.
All manuals and user guides at all-guides.com
1. Adjust Menu
→ 4. TXRX Adjustment
→ 5. MON Indicator Adjustment
Adjusted to 8
4. NAV equipment Setting
→ 2. MAG Compass Setting
Off
: Heading correction is not conducted.
On
: Heading correction is conducted.
4-19

Advertisement

Table of Contents
loading