S4-5
Set the time to th gyro alarm
0.5 seconds ..............[OFF]
5 seconds .................[ON]
S4-6
Set the sensor
Use the gyro.............[OFF]
Use the NMEA ........[ON]
S4-7, 8
Set the baud rate
S4-7
S4-8
S5: Make settings for S5 according to the type of gyro compass. Refer to the S5 setting table.
S5-1
Make settings according to the type of gyro compass.
Synchro signal ............................ [OFF]
Step signal................................... [ON]
S5-2,3 Make settings according to the gyration ratio.
S5-2
S5-3
S5-4
Set the gyration direction.
Normal (clockwise)..................... [OFF]
Reverse (counterclockwise) ........ [ON]
S5-5
Set the log type.
Pulse signal ................................. [OFF]
Synchro signal ............................ [ON]
S5-6
Not in use
S5-7,8 Set the log ratio.
S5-7
S5-8
4800
9600
19200
38400
OFF
ON
OFF
OFF
OFF
ON
360X
180X
90X
36X
OFF
ON
OFF
ON
OFF
OFF
ON
ON
Pulse/NM (pulse signal)
800
400
200
Gyration/NM (synchro signal)
360X
180X
90X
OFF
ON
OFF
OFF
OFF
ON
3-17
ON
ON
100
30X
ON
ON