Setting Of Bearing Pulses From Antenna (Output Pulse); Setting Of Bearing Pulses From Antenna; → 6. Output Pulse - JRC JMA-5312-6HS Installation Manual

Marine radar equipment
Hide thumbs Also See for JMA-5312-6HS:
Table of Contents

Advertisement

[II] TNI Blank Area Creation (Make Sector)
Procedures
1. Transmit the radar.
2. Open the Serviceman Menu.
3. Perform the following menu open procedure to open the TNI Blank
setting menu.
4. Press the 2. Make Sector button in the menu.
5. Set the starting bearing of the TNI blank by operating the [EBL] dial, and
press the [ENT] key.
6. Set the ending bearing of the TNI blank by operating the [EBL] dial, and
press the [ENT] key.
4.12
SETTING OF BEARING PULSES FROM
ANTENNA (OUTPUT PULSE)
Set the output value of bearing pulses from the antenna. The system can set 2048 pulses or 4096 pulses. This
setting is enabled only when an antenna of NKE-2254-7/9/6HS (JMA-5322-7/9/6HS), NKE-1130 (JMA-5332-12) is
used.
Procedures
1. Open the Serviceman Menu.
2. Perform the following menu open procedure to open the Output Pulse
setting menu.
3. Set the number of pulses to be output by the antenna.
2048
4096
* If a NKE-2103 (JMA-5312-6/6HS) antenna is used, 2048 is always set.
All manuals and user guides at all-guides.com
2. Installation Menu
→ 9. Next
→ 2. TNI Blank
1. Adjust Menu
→ 4. TXRX Adjustment
→ 6. Output Pulse
: 2048 pulses per antenna rotation (Recommended value)
: 4096 pulses per antenna rotation
4-
14
4

Advertisement