[II] Transmission Monitor Adjustment (MON Indicator Adjustment)
Adjust the circuit for monitoring the transmission performance of the radar equipment.
Note:
The radar system is equipped with an interswitch.
For adjusting the performance unit, set the interswitch connection to straight, i.e. No.1 scanner is
connected to No.1 display unit as the Master.
Procedures
1. Open the Serviceman Menu.
2. Perform the following menu open procedure to open the performance
3. Increase or decrease the adjustment value so that the performance
4. Press the
Note:
During performance monitor adjustment, all acquisitions by the target tracking function are released.
The released target acquisitions are not recovered.
4.18

MAGNET COMPASS SETTING

Set the correction value, when the radar receive HDM sentence from magnet compass or the variation of HDG is
NULL.
Procedures
1. Press the [RADAR MENU] key twice.
2
2. Press the [1] key.
monitor Indicator Adjustment menu.
1. Adjust Menu
→ 4. TXRX Adjustment
→ 5. MON Indicator Adjustment
monitor level indicator will be adjusted to "8."
Exit
button to close the adjustment menu.
Open the MAG Compass Setting menu by performing the following
menu operation.
4. NAV equipment Setting
→ 2. MAG Compass Setting
The Heading Correction function can be turned on / off.
Off
: Heading correction is not conducted.
On
: Heading correction is conducted.
Adjusted to 8