Q5Z Global Laser Measurement Sensor With IO-Link Instruction Manual
Chapter Contents
2.1 TEACH Mode .............................................................................................................................................................................................. 9
2.2 Response Speed ......................................................................................................................................................................................... 9
2.3 Gain and Sensitivity ..................................................................................................................................................................................... 9
2.4 Delay Timer ................................................................................................................................................................................................ 10
2.5 Channel 1 Output ...................................................................................................................................................................................... 10
2.6 Channel 2 Output/Function ....................................................................................................................................................................... 10
Chapter 2
The Q5Z Global sensor is preconfigured for ease of installation.
The following sections explain each setting. All of these settings can be adjusted from their factory default setting in the field
using either an RSD or an IOLink interface.
For assistance configuring the sensor, contact Banner Engineering.
TEACH Mode
2.1
The default Teach mode for Output 1 is preconfigured to one of the following options.
•
Twopoint static background suppression
•
Dynamic background suppression
•
Onepoint window (foreground suppression)
•
Onepoint background suppression
•
Dual (intensity + distance) window
See "TEACH Procedures" on page
NOTE: For one-point window (foreground suppression), the window is automatically determined during
the teach process. If a specific window size is needed, contact Banner Engineering.
Response Speed
2.2
The response speed is preconfigured to one of the following options.
Use the following tables to choose a response speed that is appropriate for the application. Slowing down the response
speed can assist in detecting dark targets.
Response Speed
3 ms
5 ms
15 ms
25 ms
50 ms
Gain and Sensitivity
2.3
The gain setting is preconfigured to one of the following options.
High excess gain is not available for 3 or 5millisecond response speeds.
June 23, 2023
Configuration Description
19 for additional information and remote input TEACH instructions.
Response Speed in Sync
Mode
6 ms
1000 µs
10 ms
1600 µs
30 ms
3 ms
50 ms
5 ms
100 ms
10 ms
© Banner Engineering Corp.
Repeatability
Ambient Light Rejection
Disabled
Enabled
Enabled
Enabled
Enabled
Excess Gain
See Excess Gain in "Specifi
cations " on page
27