Chapter 2 Configuration Description; Teach Mode; Response Speed; Gain And Sensitivity - Banner Q5Z Instruction Manual

Global laser measurement sensor with io-link
Hide thumbs Also See for Q5Z:
Table of Contents

Advertisement

 
Q5Z Global Laser Measurement Sensor With IO-Link Instruction Manual 
Chapter Contents
2.1  TEACH Mode  .............................................................................................................................................................................................. 9
2.2  Response Speed ......................................................................................................................................................................................... 9
2.3  Gain and Sensitivity ..................................................................................................................................................................................... 9
2.4 Delay Timer  ................................................................................................................................................................................................ 10
2.5  Channel 1 Output  ...................................................................................................................................................................................... 10
2.6  Channel 2 Output/Function  ....................................................................................................................................................................... 10
 
Chapter 2
 The Q5Z Global sensor is pre­configured for ease of installation. 
The following sections explain each setting. All of these settings can be adjusted from their factory default setting in the field
using either an RSD or an IO­Link interface. 
For assistance configuring the sensor, contact Banner Engineering. 
 TEACH Mode 
2.1
 The default Teach mode for Output 1 is pre­configured to one of the following options. 
Two­point static background suppression 
Dynamic background suppression 
One­point window (foreground suppression) 
One­point background suppression 
Dual (intensity + distance) window 
 See "TEACH Procedures" on page
NOTE: For one-point window (foreground suppression), the window is automatically determined during
the teach process. If a specific window size is needed, contact Banner Engineering. 
 Response Speed 
2.2
 The response speed is pre­configured to one of the following options. 
 Use the following tables to choose a response speed that is appropriate for the application. Slowing down the response 
speed can assist in detecting dark targets. 
Response Speed 
3 ms 
5 ms 
15 ms 
25 ms 
50 ms 
 Gain and Sensitivity 
2.3
The gain setting is pre­configured to one of the following options. 
 High excess gain is not available for 3­ or 5­millisecond response speeds. 
June 23, 2023
Configuration Description
19 for additional information and remote input TEACH instructions. 
Response Speed in Sync
Mode 
6 ms 
1000 µs 
10 ms 
1600 µs 
30 ms 
3 ms 
50 ms 
5 ms 
100 ms 
10 ms 
© Banner Engineering Corp.
Repeatability 
Ambient Light Rejection 
 Disabled 
 Enabled 
 Enabled 
Enabled 
Enabled 
 Excess Gain 