Chapter 7 Io-Link Interface - Banner Q5Z Instruction Manual

Global laser measurement sensor with io-link
Hide thumbs Also See for Q5Z:
Table of Contents

Advertisement

 
Q5Z Global Laser Measurement Sensor With IO-Link Instruction Manual 
Chapter Contents
 
Chapter 7
IO-Link Interface
IO-Link is a point-to-point communication link between a master device and sensor. Use IO-Link to parameterize sensors and
transmit process data automatically.  
For the latest IO­Link protocol and specifications, see www.io-link.com. 
Each IO­Link device has an IODD (IO Device Description) file that contains information about the manufacturer, article num­
ber, functionality etc. This information can be easily read and processed by the user. Each device can be unambiguously
identified via the IODD as well as via an internal device ID. Download the Q5Z Global's IO­Link IODD package (p/n 206833)
from Banner Engineering's website at www.bannerengineering.com. 
Banner has also developed Add On Instruction (AOI) files to simplify ease­of­use between the Q5Z Global, multiple third­par­
ty vendors' IO-Link masters, and the Logix Designer software package for Rockwell Automation PLCs. Three types of AOI
files for Rockwell Allen-Bradley PLCs are listed below. These files and more information can be found
at www.bannerengineering.com. 
Process Data AOIs—These files can be used alone, without the need for any other IO­Link AOIs. The job of a Process Data 
AOI is to intelligently parse out the Process Data word(s) in separate pieces of information. All that is required to make use of
this AOI is an EtherNet/IP connection to the IO-Link Master and knowledge of where the Process Data registers are located
for each port. 
Parameter Data AOIs—These files require the use of an associated IO­Link Master AOI. The job of a Parameter Data AOI, 
when working in conjunction with the IO­Link Master AOI, is to provide quasi­realtime read/write access to all IO­Link para­
meter data in the sensor. Each Parameter Data AOI is specific to a given sensor or device. 
IO-Link Master AOIs—These files require the use of one or more associated Parameter Data AOIs. The job of an IO­Link 
Master AOI is to translate the desired IO­Link read/write requests, made by the Parameter Data AOI, into the format a specif­
ic IO­Link Master requires. Each IO­Link Master AOI is customized for a given brand of IO­Link Master. 
Add and configure the relevant Banner IO-Link Master AOI in your ladder logic program first; then add and configure Banner
IO­Link Device AOIs as desired, linking them to the Master AOI as shown in the relevant AOI documentation. 
 
June 23, 2023
© Banner Engineering Corp.
25

Advertisement

Table of Contents
loading

Table of Contents