Multiple Spectrals (Dmx Control) - SHOWTEC Spectral PC 1800Z IP Manual

Table of Contents

Advertisement

Spectral PC 1800Z IP

Multiple Spectrals (DMX Control)

01) Fasten the effect light to a firm trussing. Leave at least 0,5 meter on all sides for air circulation.
02) Always use a safety cable (ordercode 70140 / 70141).
03) Use a 3-pin XLR cable to connect the Spectrals and other devices.
04) Link the units as shown in fig. 04. Connect a light controller to the first unit's DMX "in" socket, using a
DMX cable. Connect the first unit's "out" socket with the second unit's "in" socket, using a DMX
cable. Link the second, third, and fourth units.
05) Supply electric power: Plug electric mains power cords into each unit's special IP rated Pro power IN
socket, then plug the other end of the mains power cord into proper electric power supply sockets,
starting with the first unit. Do not supply power before the whole system is set up and connected
properly.
Multiple Spectrals DMX Set Up
Ordercode: 43553
Note : Link all cables before connecting electric power
11
Fig. 04

Advertisement

Table of Contents
loading

This manual is also suitable for:

43553

Table of Contents