SHOWTEC Performer 2000 Fresnel DDT MKII V1 Manual

Hide thumbs Also See for Performer 2000 Fresnel DDT MKII V1:

Advertisement

Quick Links

MANUAL
ENGLISH
Performer 2000 Fresnel DDT MKII V1
Ordercode: 33037
Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands

Advertisement

Table of Contents
loading

Summary of Contents for SHOWTEC Performer 2000 Fresnel DDT MKII V1

  • Page 1 MANUAL ENGLISH Performer 2000 Fresnel DDT MKII V1 Ordercode: 33037 Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands...
  • Page 2: Table Of Contents

    Performer 2000 Fresnel DDT MKII Table of contents Warning ....................................3 Safety Instructions ................................. 3 Operating Determinations ............................5 Rigging .................................... 5 Connection with the mains............................6 Return Procedure ................................7 Claims ....................................7 Description of the device ..............................8 Features ..................................
  • Page 3 Performer 2000 Fresnel DDT MKII Troubleshooting ................................25 No Light ..................................25 No Response to DMX..............................25 Product Specifications ..............................27 Dimensions ..................................28 Notes ....................................29 Ordercode: 33037...
  • Page 4: Warning

    Save the carton and all packing materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing. Your shipment includes:  Showtec Performer 2000 Fresnel DDT MKII  1 color frame ...
  • Page 5  If your Showtec device fails to work properly, discontinue the use immediately. Pack the unit securely (preferably in the original packing material), and return it to your Showtec dealer for service.
  • Page 6: Operating Determinations

    Performer 2000 Fresnel DDT MKII  Repairs, servicing and electric connection must be carried out by a qualified technician.  WARRANTY: Till one year after date of purchase. Operating Determinations • This device is not designed for permanent operation. Consistent operation breaks will ensure that the device will serve you for a long time without defects.
  • Page 7: Connection With The Mains

    Performer 2000 Fresnel DDT MKII Connection with the mains Connect the device to the mains with the power-plug. Always check if the right color cable is connected to the right place. International EU Cable UK Cable US Cable BROWN YELLOW/COPPER PHASE BLUE BLACK...
  • Page 8: Return Procedure

    Performer 2000 Fresnel DDT MKII Return Procedure Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. Call Highlite 0031-455667723 or mail aftersales@highlite.nl and request an RMA prior to shipping the fixture.
  • Page 9: Description Of The Device

    Performer 2000 Fresnel DDT MKII Description of the device Features The Showtec Performer 2000 Fresnel DDT MKII is a theater spotlight fixture with high output and great effects.  Input voltage: 100-240V AC, 60/50Hz  Light source: 1x 200W CITIZEN LED ...
  • Page 10 Performer 2000 Fresnel DDT MKII Fig. 02 01) Front cap 02) Front lens cover 03) Lens tube 04) Front plate 05) Top cover 06) Adjustment screw 07) Mounting bracket with inclination screw 08) Heat-sink bracket 09) Lens plate 10) Lens frame 11) Collecting lens 12) LED board 13) Thermal switch holder...
  • Page 11: Backside

    Performer 2000 Fresnel DDT MKII Backside Fig. 03 29) PowerCON power connector 100-240V IN 30) 3-pin DMX signal connector IN 31) 5-pin DMX signal connector IN 32) 3-pin DMX signal connector OUT 33) 5-pin DMX signal connector OUT 34) PowerCON power connector 100-240V OUT 35) Voltage switch 115/230V 36) Fuse T3,15AL/250V 37) LED display + menu buttons...
  • Page 12: Installation

    Performer 2000 Fresnel DDT MKII Installation Remove all packing materials from the Performer 2000 Fresnel DDT MKII. Check if all foam and plastic padding is removed. Connect all cables. Do not supply power before the whole system is set up and connected properly. Always disconnect from electric mains power supply before cleaning or servicing.
  • Page 13: Setting The Angle

    Performer 2000 Fresnel DDT MKII Setting the angle 01) Loosen the adjustment screw (do not remove them). 02) Tilt the fixture to the desired position. 03) Tighten the adjustment screw to secure the fixture in position. Fig. 05 Ordercode: 33037...
  • Page 14: Control Modes

    Performer 2000 Fresnel DDT MKII Control Modes There are 3 modes: • Stand-alone • Master/Slave • DMX-512 (1CH, 2CH, 5CH) One Performer (Stand-alone) 01) Fasten the effect light to a firm trussing. Leave at least 0,5 meter on all sides for air circulation. 02) Plug the end of the electric mains power cord into a proper electric power supply socket.
  • Page 15: Multiple Performers (Dmx Control)

    Performer 2000 Fresnel DDT MKII Multiple Performers (DMX Control) 01) Fasten the effect light to a firm trussing. Leave at least 0,5 meter on all sides for air circulation. 02) Always use a safety cable (ordercode 70140 / 70141). 03) Use a 3-pin/5-pin XLR cable to connect the Performers and other devices. 04) Link the units as shown in fig.
  • Page 16: Fixture Linking

    Performer 2000 Fresnel DDT MKII Fixture Linking You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to run synchronized shows of two or more fixtures set to a master/slave operating mode. The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support.
  • Page 17: Control Panel

    Performer 2000 Fresnel DDT MKII The Performer 2000 Fresnel DDT MKII can be operated with a controller in control mode or without the controller in stand-alone mode. Control Panel A) MENU button ENTER button C) DOWN button D) UP button ZOOM control LED display G) DIMMER control...
  • Page 18: Menu Overview

    Performer 2000 Fresnel DDT MKII Menu Overview Ordercode: 33037...
  • Page 19: Main Menu Options

    Performer 2000 Fresnel DDT MKII Main Menu Options DMX-512 Mode Run Mode Zoom/Dimmer settings White color calibration General settings Motor reset 1. DMX-512 Mode In this mode you can set the DMX starting address. 01) While in the main menu, press the UP/DOWN buttons until the display shows 02) Press the ENTER button to open the menu.
  • Page 20: Zoom/Dimmer Settings

    Performer 2000 Fresnel DDT MKII 3. Zoom/Dimmer settings You can enter the Zoom/Dimmer settings by pressing the ZOOM/DIMMER controls (on the control panel (37)) twice. You can also gain access by following the instructions below. 01) While in the main menu, press the UP/DOWN buttons until the display shows 02) Press the ENTER button to open the menu.
  • Page 21: General Settings

    Performer 2000 Fresnel DDT MKII 5. General settings 01) While in the main menu, press the UP/DOWN buttons until the display shows 02) Press the ENTER button to open the menu. 03) If the display shows , you need to insert a key combination which will unlock the menu. 04) Insert the key combination by pressing the buttons in the following order: UP, DOWN, UP, DOWN, ENTER.
  • Page 22: Dimmer Speed

    Performer 2000 Fresnel DDT MKII 5.2. Dimmer speed 01) When the display shows , press the ENTER button to open the menu. 02) Press the UP/DOWN buttons to choose one of the 5 options: Dimmer speed, from fast to slow 5.3.
  • Page 23: Save Dmx/Blackout

    Performer 2000 Fresnel DDT MKII 5.7. Save DMX/Blackout 01) When the display shows , press the ENTER button to open the menu. 02) Press the UP/DOWN buttons to toggle between the 2 options: Blackout DMX data save 03) If the display shows , the Performer will blackout the output, in case of the DMX signal error.
  • Page 24: Dmx Channels

    Performer 2000 Fresnel DDT MKII DMX Channels 1 Channel Channel 1 – Dimmer 0-255 Gradual dimmer adjustment, 0-100% 2 Channels Channel 1 – Dimmer 0-255 Gradual dimmer adjustment, 0-100% Channel 2 – Fine dimmer 0-255 Fine dimmer adjustment 5 Channels Channel 1 –...
  • Page 25: Cleaning

    Performer 2000 Fresnel DDT MKII Cleaning Please follow the next recommendations when cleaning and inspecting lenses and reflectors: Do not use glass or window type cleaners on lenses (glass or polymer) or reflectors. Do not use abrasive materials such as steel wool. Replace lenses if they contain visible damage (cracks or deep scratches) which that may impair their effectiveness.
  • Page 26: Troubleshooting

    Suspect three potential problem areas as: the power supply, the LEDs, the fuse. 01) Power supply. Check if the unit is plugged into an appropriate power supply. 02) The LEDs. Return the Performer to your Showtec dealer. 03) The fuse. Replace the fuse. See page 24 for replacing the fuse.
  • Page 27 Performer 2000 Fresnel DDT MKII Problem Probable cause(s) Solution • Check if power is switched on and One or more No power to the fixture fixtures do not cables are plugged in function at all Primary fuse blown • Replace fuse Fixtures reset The controller is not connected.
  • Page 28: Product Specifications

    Performer 2000 Fresnel DDT MKII Product Specifications Model: Showtec Performer 2000 Fresnel DDT MKII Input voltage: 100-240V AC, 60/50Hz Power consumption: 180W (full output) DMX linking: 30pcs Fuse: T3,15AL/250V Dimensions: 255 x 380 x 388 mm (LxWxH) Weight: 6,8 kg...
  • Page 29: Dimensions

    Performer 2000 Fresnel DDT MKII Dimensions Ordercode: 33037...
  • Page 30: Notes

    Performer 2000 Fresnel DDT MKII Notes Ordercode: 33037...
  • Page 31 Performer 2000 Fresnel DDT MKII Ordercode: 33037...
  • Page 32 ©2017 Showtec...

This manual is also suitable for:

33037

Table of Contents