Summary of Contents for SHOWTEC Performer 2500 Fresnel Tungsten V1
Page 1
USER MANUAL ENGLISH Performer 2500 Fresnel Tungsten Product code: 33141 Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands...
Page 2
Performer 2500 Fresnel Tungsten Preface Thank you for purchasing this Showtec product. The purpose of this user manual is to provide instructions for the correct and safe use of this product. Keep the user manual for future reference as it is an integral part of the product. The user manual shall be stored at an easily accessible location.
Performer 2500 Fresnel Tungsten Table of contents Introduction ................................4 Before Using the Product ..........................4 Intended Use ............................... 4 Product Lifespan ..............................4 LEDs Lifespan ............................... 4 Text Conventions ..............................4 Symbols and Signal Words ..........................5 Symbols on the Information Label ........................5 Safety ..................................
Page 4
Performer 2500 Fresnel Tungsten Dimming Curves ..........................28 DMX Error ..............................28 PWM Rate ............................28 Full Power CCT ............................29 Performance ............................29 Mcon ..............................29 Disp Key (Display Lock) ..........................29 Disp Time (Display Time) ..........................29 CCT (Correlated Color Temperature Control) ..................30 CCT ...............................30 CALR ..............................30 Information ..............................30 Fixture Hours ............................30 Version ..............................31...
After unpacking, check the contents of the box. If any parts are missing or damaged, contact your Highlite International dealer. Your shipment includes: ● Showtec Performer 2500 Fresnel Tungsten ● Schuko to True1 pro power cable (1,4 m) ● 1 x safety cable ●...
Performer 2500 Fresnel Tungsten ● References: References to chapters and parts of the device are in bold lettering, for example: “Refer to 2. Safety”, “turn the adjustment screw (02)” ● 0–255: Defines a range of values ● Notes: Note: (in bold lettering) is followed by useful information or tips Symbols and Signal Words Safety notes and warnings are indicated throughout the user manual by safety signs.
Performer 2500 Fresnel Tungsten Safety Important Read and follow the instructions in this user manual before installing, operating or servicing this product. The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual. Warnings and Safety Instructions DANGER Danger for children For adult use only.
Page 8
Performer 2500 Fresnel Tungsten WARNING Risk of burns due to hot surface The surface and the inner parts of the device can become very hot during operation. ● Do not touch the device during operation. ● Allow the device to cool down for at least 15 minutes before handling. WARNING Risk of epileptic shock Strobe lighting can trigger seizures in photosensitive epilepsy.
Performer 2500 Fresnel Tungsten ● If the device is exposed to extreme temperature variations (e.g. after transportation), do not switch it on immediately. Let the device reach room temperature before switching it on, otherwise it may be damaged by the formed condensation. ●...
Performer 2500 Fresnel Tungsten Description of the Device The Performer 2500 Fresnel Tungsten is equipped with a dual color LED engine. This engine is customized with specially selected colors with specified wavelengths, ensuring a high CRI of 95 and even beam. The Performer has a CCT channel enabling you to set the color temperature between 2700–4500 K.
Performer 2500 Fresnel Tungsten Back View Fig. 03 Safety eye Pro True1 power connector OUT Fuse F5AL/250 V 5-pin DMX connector IN 5-pin DMX connector OUT Pro True1 power connector IN Product code: 33141...
Performer 2500 Fresnel Tungsten Product Specifications Model: Performer 2500 Fresnel Tungsten Electrical: Input voltage: 100–240 V AC, 50/60 Hz Power consumption: 265 W Max. power: 280 W Power factor: 0,95 Fuse: F5AL/250 V Physical: Dimensions: 470 x 380 x 450 mm (LxWxH) Weight: 10 kg Optics:...
Performer 2500 Fresnel Tungsten Optional Accessories The Performer 2500 Fresnel Tungsten is delivered without accessories. You can additionally purchase the following accessories: Product code: 33161 (Barndoor for Performer 2500 Fresnel) Dimensions Fig. 04 Fig. 05 Product code: 33141...
Performer 2500 Fresnel Tungsten Fig. 06 Installation Safety Instructions for Installation WARNING Incorrect installation can cause serious injuries and damage of property. If trussing systems are used, installation must be carried out only by instructed or skilled persons. Follow all applicable European, national and local safety regulations concerning rigging and trussing. Personal Protective Equipment During installation and rigging wear personal protective equipment in compliance with the national and site-specific regulations.
Page 15
Performer 2500 Fresnel Tungsten To mount the device, follow the steps below: 01) Use a clamp to attach the device to the supporting structure, as shown in Fig. 07. Make sure that the device cannot move freely. Optionally, you can use the Slide Complete to attach the device. 02) Secure the device with a secondary suspension, for example a safety cable.
Performer 2500 Fresnel Tungsten Angle Adjustment You can adjust the angle of the device with the 2 adjustment screws (03). 01) Turn the adjustment screws (03) counterclockwise to release them. 02) Tilt the device to the desired angle (see Fig. 08). 03) Turn the adjustment screws (03) clockwise to tighten them.
Performer 2500 Fresnel Tungsten Barndoor Installation The barndoor holder is equipped with a spring-loaded retaining clip. This prevents the barndoor from falling out. Release the retaining clip by pressing the lock towards the lens and pressing on the longer side of the screw.
Performer 2500 Fresnel Tungsten Connecting to Power Supply DANGER Electric shock caused by short-circuit The device accepts AC mains power at 100–240 V and 50/60 Hz. Do not supply power at any other voltage or frequency to the device. This device falls under IEC protection class I. Make sure that the device is always electrically connected to the ground (earth).
Performer 2500 Fresnel Tungsten Setup Warnings and Precautions Attention Connect all data cables before supplying power. Disconnect power supply before connecting or disconnecting data cables. Stand-alone Setup When the Performer 2500 Fresnel Tungsten is not connected to a controller or to other devices, it functions as a stand-alone device.
Performer 2500 Fresnel Tungsten DMX Cables Shielded twisted-pair cables with 5-pin XLR connectors must be used for reliable DMX connection. You can purchase DMX cables directly from your Highlite International dealer or make your own cables. If you use 3-pin XLR audio cables for DMX data transmission, this may lead to signal degradation and unreliable operation of the DMX network.
Performer 2500 Fresnel Tungsten DMX Linking To connect multiple devices on one DMX data link, follow the steps below: Use a 5-pin DMX cable to connect the DMX OUT connector of the lighting controller to the DMX IN connector of the first device. 02) Connect the first device’s DMX OUT connector to the second device’s DMX IN connector with a 5-pin DMX cable.
Performer 2500 Fresnel Tungsten Operation Safety Instructions for Operation Attention This device must be used only for the purposes it is designed for. This device is intended for professional use as a theater spot. It is suitable only for indoor installation. This device is not suitable for households and for general lighting.
Use the rotatable controls to adjust settings in Knob mode. See 6.6.1. Knob Mode on page 25 for more information. Start-up Upon start-up the display will show a splash screen with the logo of Showtec. Press any button to enter the password and/or enter the Main Menu. Note: ●...
Performer 2500 Fresnel Tungsten Main Menu Options The main menu has the following options: 01) Press the UP/DOWN buttons to navigate through the main menu. 02) Press the ENTER button to open the submenus. Note: Some of the submenus require a password. The default password is pressing the UP/DOWN buttons in the following order: UP, DOWN, UP, DOWN, ENTER.
Performer 2500 Fresnel Tungsten Mode 2 In this menu you can set the dimmer, CCT and the dimming curve. 01) Turn the controls (D/E/F) to adjust settings. The adjustment ranges are: ● D: Dimmer, from dark to brightest (0–100 %) ●...
Performer 2500 Fresnel Tungsten Personality (DMX Channel Modes) In this menu you can set the DMX channel mode (personality). 01) Press the UP/DOWN buttons to select the desired DMX channel mode. There are 5 options available: UNO: 1 channel VW.F: 6 channels DOS: 2 channels...
Performer 2500 Fresnel Tungsten Dimmer In this submenu you can adjust the dimmer speed. 01) Select DIMMER and press the ENTER button to open the submenu. Press the UP/DOWN buttons to choose one of the following options: ● DIM 1, DIM 2, DIM 3, DIM 4: non-linear dimmers, from fast to slow ●...
Performer 2500 Fresnel Tungsten Full Power CCT In this submenu you can set the color temperature. 01) Select FULL POWER CCT and press the ENTER button to open the submenu. Press the UP/DOWN buttons to choose the desired color temperature. The available options are: 2700 K, 3200 K, 4200 K and NORMAL.
Performer 2500 Fresnel Tungsten CCT (Correlated Color Temperature Control) In this menu you can calibrate the color temperature. This menu requires the password. The default password is pressing the UP/DOWN buttons in the following order: UP, DOWN, UP, DOWN. 01) Enter the password to access the menu. Press the ENTER button to confirm the password.
Performer 2500 Fresnel Tungsten Version In this submenu you can view the total operation time of the device. In this submenu you can view the RDM details of the device. 01) Press the UP/DOWN buttons to choose between the following options: ●...
Performer 2500 Fresnel Tungsten Troubleshooting This troubleshooting guide contains solutions to problems which can be carried out by an ordinary person. The device does not contain user-serviceable parts. Unauthorized modifications to the device will render the warranty void. Such modifications may result in injuries and material damage.
Performer 2500 Fresnel Tungsten Maintenance Safety Instructions for Maintenance DANGER Electric shock caused by dangerous voltage inside Disconnect power supply before servicing or cleaning. WARNING Risk of burns due to hot surface Allow the device to cool down for at least 15 minutes before servicing or cleaning. Preventive Maintenance Attention Before each use, examine the device visually for any defects.
Performer 2500 Fresnel Tungsten Basic Cleaning Instructions The external lens of the device must be cleaned periodically in order to optimize the light output. The cleaning schedule depends on the conditions at the site where the device is installed. When smoke or fog machines are used at the site, the device will need more frequent cleaning.
Performer 2500 Fresnel Tungsten Deinstallation, Transportation and Storage Instructions for Deinstallation WARNING Incorrect deinstallation can cause serious injuries and damage of property. ● Let the device cool down before dismounting. ● Disconnect power supply before deinstallation. ● Always observe the national and site-specific regulations during deinstallation and derigging of the device.