THE SAUNA ROOM SHALL BE PROVIDED WITH PROPER VENTILATION
MINIMUM CLEARANCES, MIN-MAX SPACE, ADEQUATE VENTILATION
LA CABINE DU SAUNA DOIT ÊTRE SUFFISAMMENT AÉRÉE
DÉGAGEMENT MINIMAL, ESPACE MIN.-MAX., AÉRATION ADÉQUATE
MODEL/MODÉLE
A min.
PO10-U1, PO12-U1,
5"
PO10-U3, PO12-U3
PO15-U1, PO15-U3
6"
VENTILATION, MIN. SQ.IN. INLET AND OUTLET
AÉRATION, SURFACE MIN. ENTRÉE ET SORTIE
10 kW
30 sq.in.
12.5 kW and 15 kW
A
AIR IN
ARRIVÉE
D'AIR
4"
CONCRETE
BÉTON
Figure 3.
FENCE
CEINTURE DE
PROTECTION
A
Figure 4.
45 sq.in.
6"
20"
FENCE
CEINTURE DE
PROTECTION
20"
4"
TILE
CARRELAGE
1"
4"
MIN.
FR
HEATER MIN. CLEARANCE FROM WALL AND FENCE
DÉGAGEMENT MIN. ENTRE LE PÔELE ET LA PAROI ET
LA CEINTURE DE PROTECTION
AIR OUT
ÉVACUATION
D'AIR
4"
WOOD FENCE
CEINTURE DE
PROTECTION
EN BOIS
Figure 5.
HEATER MIN. CLEARANCE FROM BENCHES
DÉGAGEMENT MIN. ENTRE LE PÔELE ET LES BANCS
Figure 6.
Figure 7.
A
A
4"
A
BENCH
BANC
11