Download Print this page
Harvia KIP-30-W1 Owner's/Operator's Manual
Hide thumbs Also See for KIP-30-W1:

Advertisement

Quick Links

Owner's/Operator's Manual
Sauna heater installation, wiring, operating instructions, trouble shooting, maintenance
and guarantee.
IMPORTANT! This manual must be left with owner, manager
or operator of Sauna after it is used by electrician!
MODEL
KIP-30-B1
KIP-45-B1
KIP-60-B1
KIP-80-B1
KIP-30-B3
KIP-45-B3
KIP-60-B3
KIP-80-B3
CONTROLS
CG170-U1
CG170-U3
CX170-U1
CX170-U3
Sauna Specialiste Inc.
1085 Desserte Nord Autoroute 440 Ouest
Laval, QC H7L 3W3
Toll free: 1 855-689-2422
Harvia US Inc.
3567 Jefferson St. N,
Lewisburg, WV 24901
+1 304-497-3991
02052023/Y05-0623
MODEL
KIP-30-W1
KIP-45-W1
KIP-60-W1
KIP-80-W1
MODEL
KIP-30-W3
KIP-45-W3
KIP-60-W3
KIP-80-W3
►12

Advertisement

loading

Summary of Contents for Harvia KIP-30-W1

  • Page 1 KIP-30-B3 KIP-45-B3 KIP-60-B3 KIP-80-B3 CONTROLS CG170-U1 CG170-U3 CX170-U1 CX170-U3 Sauna Specialiste Inc. 1085 Desserte Nord Autoroute 440 Ouest Laval, QC H7L 3W3 Toll free: 1 855-689-2422 Harvia US Inc. 3567 Jefferson St. N, Lewisburg, WV 24901 ►12 +1 304-497-3991 02052023/Y05-0623...
  • Page 2 < 0°C / < 32 °F 18-25°C / +64-77°F Overheat protector of the device can also go off at temperatures below -5˚C / 23˚F (sto- rage, transport, environment). Before instal- lation take the device to a warm environment. The overheat protector can be reset when the tempera- ture of the device is approx 18˚C / 64˚F.
  • Page 3 THE SAUNA ROOM SHALL BE PROVIDED WITH PROPER VENTILATION Note: Control panel and power unit must be installed in a dry place; away from spa, pool or shower; not outdoors. A WIRE ROOM LIGHT receptacle shall not be installed inside the sauna room. #14 AWG 194°F/ 90°C Note (only in Canada): Sauna heaters shall not be subjected to water spray.
  • Page 4: Sauna Room Ventilation

    THE SAUNA ROOM SHALL BE PROVIDED WITH PROPER VENTILATION WALL-MOUNTED HEATERS-MINIMUM CLEARANCES, MIN-MAX SPACE, ADEQUATE VENTILATION min. 1000 mm 360° min. 500 mm 180° Figure 2. SAUNA ROOM VENTILATION A. Placement area for air supply vent (Ø 50 – The air in the sauna room should change six times 100 mm).
  • Page 5 Internal wiring only Internal wiring only 240 V 1 PHASE HEATER 208 V 3 PHASE HEATER KIP-30-B1 / KIP-45-B1 / KIP-60-B1 / KIP-80-B1 KIP-30-B3 / KIP-45-B3 / KIP-60-B3 / KIP-80-B3 TIMER TIMER LIMIT CONTROL LIMIT CONTROL GROUND LINE 1 GROUND LINE 2 LINE 1 LINE 3...
  • Page 6 Before testing heater, fill rock cavity with igneous hooking up electrical wires to junction box of heater, stones purchased from an official Harvia distribu- remove capillary tubing and bulb from junction box tor and fasten metal rock guard at top of heater.
  • Page 7 Internal wiring only Internal wiring only 208 V 3 PHASE HEATER 240 V SINGLE PHASE HEATER KIP-30-W3 / KIP-45-W3 / KIP-60-W3 / KIP-80-W3 KIP-30-W1 / KIP-45-W1 / KIP60-W1 / KIP-80-W1 HEATING ELEMENTS CONTACTOR LIMIT CONTROL 1 2 3 4 GROUND...
  • Page 8: Troubleshooting

    Use only the stones which are purchased from an (70 – 85 °C) normal sauna temperature): official harvia distributor. Wash stones with water hose and place inside of heater box so that rocks 1. You must allow at least 30 minutes for Sauna are between and around heating elements.
  • Page 9 I. FLOORING Overheat protector of the device can also go off at temperatures below -5˚C / 23˚F (stor- concrete, ceramic tile, or heavyduty Vinyl. • age, transport, environment). Before instal- J. VENTILATION lation take the device to the warm environment. should be provided by intake vent close to •...
  • Page 10: Maintenance Instructions

    We do not recommend stains or sealers as toxic vapors may appear when heated. However, 2 coats of Harvia sauna MAINTENANCE INSTRUCTIONS sealer may be used on the wood benches in a commercial Sauna, so that the wood may be more easily cleaned and kept sanitary –...
  • Page 11 KIP-60-B1/KIP-60-B3 Sauna heaters type -W1, W3 without parts nr 12, 17 and 18 JH30B2401 - JH80W2083 H12/94 JF30B2401 - JFIN802083 H12/94 Manufacturer: Harvia Oy, P.O. Box 12 (Teollisuustie 1–7), FI-40951 Muurame, Finland...
  • Page 12 GUARANTEE This HARVIA SAUNA heater is guaranteed for one be heated for at least 30 minutes before water is year from date of purchase, and includes all heater poured over the stones; only one or two dippers parts such as thermostat, controls, contactors, etc.