Connecting the unit

6.5.2 Connecting softened drinking water to both connections

Prerequisite Water pressure complies with specifications (see "Unit and

6.6 Making the waste water connection

34
Image: Connecting softened drinking water to both connections
a Backflow preventer
b Connection line
c Dirt filter
If only softened drinking water is available at the installation site, use
a T-piece to connect both water connections on the unit to each
other.
connection data")
Backflow preventer installed
Pressure-tight connection line suitable for drinking water is available
1. Connect the connection line to the tap for softened drinking water
using a seal.
2. Flush the connection line thoroughly.
3. Insert dirt filters into the water connections on the unit.
4. Connect T-piece to the unit.
5. Connect the connection line for softened drinking water to the T-
piece using a seal.
6. Open the drinking water tap and check the threaded fittings for
leakage tightness.
7. Fill out the Start-up operation report.
Waste water installation tasks
Waste water installation tasks on waste water systems and the unit
may only be carried out by a specialized company that is responsible
for waste water systems. The applicable regional regulations,
standards and guidelines must be observed, as well as the
connection conditions imposed by the operator of the waste water
company responsible.
Installation instructions
f
a
b
c
d
e
d T-piece
e Seal
f Softened drinking water