3 Installation
3.2

Fastening the panel-mounting thermostat

Operating posi-
any
tion

3.2.1 Fasting the switching head

Type EM-80
Central fastening
with central
( 1 ) Cap nut M10 x 1 (width
fastening
( 2 ) Fastening nut M10 x 1
( 3 ) Panel
( 4 ) Restart knob
Type
EM-80
Type EM-20-E,
With two M3 screws
EM-30-E,
(M4, for extra code 704)
EM-80
on the chassis:
with
( 1 ) Screw
fastening bridge
( 2 ) Panel
Type
EM-20-E,
EM-30-E
EM-80
Extra code
(all types)
706 (as standard)
704
705
10
All manuals and user guides at all-guides.com
across flats 10)
(width across flats 13)
Dimension
(mm)
X
Y
16
6
Dimension
(mm)
X
Y
- -
- -
15
6
Dimension
(mm)
B
G
3.5
22
4.5
28
3.5
33
( 3 )
( 1 )
( 2 )
( 1 )
( 1 )
( 4 )
( 2 )

Advertisement