3 Installation
3.3.4 Sheath made of stainless steel 20, 22, 40 and 41
Capacity
Temperature
3.3.5 Sheath made of brass 20 and 40
Capacity
Temperature
3.3.6 Probe connections 50, 52 and 54
(probe making directly contact with the medium)
Material of nipple
Temperature °C
Probe material
Cu-DHP
St35 1.4571
14
All manuals and user guides at all-guides.com
Material of pipe and nipple: Stainless steel (1.4571)
8 x 0.75 mm
or conical
100 °C
92 bar
150 °C
88 bar
200 °C
83 bar
300 °C
72 bar
400 °C
67 bar
Material of pipe and nipple: CuZn, nickel plated
8 x 0.75 mm
100 °C
50 bar
150 °C
48 bar
CuZn
200
Pipe diameter Ø
10 x 0.75 mm
Maximum admissible pressure
74 bar
71 bar
67 bar
58 bar
54 bar
Pipe diameter Ø
10 x 0.75 mm
Maximum admissible pressure
40 bar
39 bar
Steel (1.0038)
Stainless steel (1.4571)
300
Device function
Ø
mm
STB, STW (STB)
4
5
6
7
8
9
10
15 x 0.75 mm
50 bar
48 bar
45 bar
39 bar
36 bar
15 x 0.75 mm
27 bar
26 bar
400
2 bar