JUMO ATH.-SE Series Operating Manual
JUMO ATH.-SE Series Operating Manual

JUMO ATH.-SE Series Operating Manual

Surface-mounting thermostats
Hide thumbs Also See for ATH.-SE Series:

Advertisement

Series ATH.-SE-..
Surface-mounting thermostats
B 603031.0
Operating Manual
00073788/2020-05-01
V4.00/EN/

Advertisement

Table of Contents
loading

Summary of Contents for JUMO ATH.-SE Series

  • Page 1 Series ATH.-SE-.. Surface-mounting thermostats B 603031.0 Operating Manual 00073788/2020-05-01 V4.00/EN/...
  • Page 2 Please read these Operating Instructions before commissioning the instrument. Keep the operating instructions in a place which is accessible to all users at all times. Please assist us to improve these operating instructions. Your sugges- tions will be welcome. Phone +49 661 6003-0 +49 661 6003-607 All necessary settings and, where appropriate, alterations inside the instrument are described in these operating instructions.
  • Page 3: Table Of Contents

    Contents Page Introduction ................5 Typographical conventions ..............5 1.1.1 Warning signs ..................... 5 1.1.2 Note signs ....................5 Application ....................6 Marking ...................... 6 Safety notes ....................6 Instrument identification ............7 Nameplate (example) ................7 Type designation ..................7 Mounting ..................
  • Page 4 Contents Page Settings ..................18 Setting the limit value ................18 Resetting the STB ................... 19 Self-monitoring ..................19 5.3.1 Behaviour in the event of a measuring system breakage ......19 5.3.2 Response to low temperature ..............19 Using the STW(STB) as STB ..............19 Instrument description ............
  • Page 5: Introduction

    1 Introduction Typographical conventions 1.1.1 Warning signs Danger This symbol is used where there may be danger to personnel if the instruc- tions are disregarded or not followed accurately. Caution This symbol is used where there may be damage to equipment if the instruc- tions are disregarded or not followed accurately.
  • Page 6: Application

    1 Introduction Application Surface-mounting thermostats Series ATH.-SE-.. are approved for monitoring installations on steel-hulled ocean-going ships (e.g. steam and boiler plant, indirect heating systems) as: ❏ Temperature monitor (TW) ❏ Safety temperature monitor STW (STB) ❏ Safety temperature limiter (STB). The versions comply with DIN EN 14597 and are approved as per the guide- lines of the Classification Societies: - DNV GL...
  • Page 7: Instrument Identification

    2 Instrument identification Nameplate (example) ( 1 ) ( 2 ) ( 3 ) (1) Type code (see type designation, below) (2) Control range / contact rating (3) Approval mark Type designation Type code Basic type 603031 ATH.-SE surface-mounted thermostat with microswitch Basic type extension ATH.-SE-2 Temperature monitor TW with changeover contact...
  • Page 8: Mounting

    3 Mounting Dimensions ATHs-SE-2, ATHs-SE-20 with sheath "20" (up to +150 °C) K M24x1,5 M 20x1,5 Ø 26 DIN 89280-Z14 G1/2...
  • Page 9 3 Mounting ATHs-SE-2 (20) with sheath "30" (up to +300 °C) K M24x1,5 Ø 90 M 20x1,5 DIN 89280-Z14 G 1/2 Ø 26 Ø ATHf-SE-70, with sheath "20" (up to +300 °C) K M24x1,5 M 20x1,5 G1/2 DIN 89280-Z14 S = max. 200 (150)
  • Page 10: Opening The Case

    3 Mounting 3.2 Opening the case Opening ✱ Unscrew the two lead-sealable cheese-head screws ( 5 ) ✱ Remove the upper part of the case ( 1 ) ( 5 ) ( 5 ) ( 1 ) Ensure that the gasket is seated correctly when reassembling! Fixing the surface-mounting thermostat Operating unrestricted...
  • Page 11: Capillary / Temperature Probe / Sheath

    Minimum permissible bending radius of the capillary is 5 mm. The temperature probe must be fitted in a JUMO sheath, otherwise the approval of the surface-mounting thermostat becomes invalid. The temperature probe must be completely submerged in the medium.
  • Page 12: Permissible Pressure At The Sheath

    3 Mounting Permissible pressure at the sheath 3.5.1 Sheaths 20 and 30 The following values refer to the maximum pressure of the probe mounting concerned. The maximum pressure which can be sealed depends on the mounting conditions and may possibly be lower. 3.5.1.1 Stainless steel sheath Material...
  • Page 13: Mounting The Probe

    3 Mounting Mounting the probe Submerge the sheath and the temperature probe (2) into the medium and ensure that the temperature probe (2) is completely submerged in the medium because otherwise, greater switching point deviations will occur. For thermostats with long- ( 1 ) distance line (abbreviation "f"), the temperature probe...
  • Page 14: Installation

    4 Installation Regulations and notes ❏ The electrical connection must only be made by qualified personnel. ❏ The choice of cable, the installation and the electrical connection must conform to the requirements of VDE 0100 “Regulations for the installation of power circuits with nominal voltages below 1000 V”, or the appropriate local regulations.
  • Page 15: Electrical Connection

    4 Installation Electrical connection ✱ Open the case. ➪ Section 3.2 "Opening the case", page 10. ✱ Pass the connection cable (cable diameter 10 — 16,5 mm) through the screw connection (3). Fitting type"X" (no special tools), screw connection up to 2.5 mm conductor cross-section.
  • Page 16: Closing The Case

    4 Installation 4.2.1 Closing the case ✱ Make sure that the plastic gasket in the lower part of the case ( 2 ) is seated correctly. On thermostats with code -70, the external reset button ( 3 ) must be located precisely on top of the internal reset button ( 4 ) for the microswitch, since this is the only way the reset button ( 3 ) can be operated from the outside.
  • Page 17 4 Installation ✱ Turn the screw connection ( 1 ) clockwise until the cable inlet is sealed and Cable relief the cable is secured against pulling out. The cable has to be protected against vibration overload by leaving sufficient extra cable length ( 2 ). ✱...
  • Page 18: Settings

    5 Settings Setting the limit value ✱ Open the case. ➪ Section 3.2 "Opening the case", page 10. ✱ Set the limit value on the set point setter ( 5 ) using a screwdriver. ( 1 ) Top stop ( 2 ) Bottom stop ( 3 ) Set point indicator ( 4 ) Scale division ( 5 ) Set point setter...
  • Page 19: Resetting The Stb

    5 Settings Resetting the STB After the temperature has fallen below the set limit value (safe temperature limit) by about 10% of the scale range, the microswitch can be reset. Action ✱ Unscrew the cap nut ✱ Press the reset but- ✱...
  • Page 20: Instrument Description

    6 Instrument description Technical data Permissible ambient Capillary Thermostat head with scale limit value temperature maximum +80 °C +80 °C in operation -40 °C -40 °C below +200°C minimum -20 °C -20 °C > 200 °C to < 300 °C Permissible on the probe during use overtempera-...
  • Page 21 6 Instrument description Operating as per EN 60 730-1 mode Type 2BL = automatic mode with microswitch disconnection in operation, which requires no auxiliary energy source. STB, STW (STB): Type 2BK = automatic mode with microswitch disconnection in operation, with fail-safe facility. Operating position unrestricted (with open-air mounting on request) Weight...
  • Page 22: Documents And Accessories

    7 Documents and accessories Prg. 603031 - Documentation - Declaration of Conformity / White Paper - Certificate - China RoHS qr-603031-en.jumo.info...