Troubleshooting Cloning Mode - Motorola CLP Series User Manual

Hide thumbs Also See for CLP Series:
Table of Contents

Advertisement

Figure 13: Cloning the Radio through a Multi-Unit Charger
5.4

Troubleshooting Cloning Mode

When and where to use:
The radio audible voice announces "Bonk" indicating that the cloning process has failed. In the event
that cloning fails, perform each of the following steps before attempting to start cloning process again.
Procedure:
1 Ensure that the batteries on both radios are fully charged and engaged properly on the radio.
2 Check the cloning cable connection on both Single-Unit Chargers (SUC).
3 Ensure that there is no debris in the charging tray or on the radio contacts and the radio contact
is touching the SUC or Multi-Unit Charger (MUC) contact firmly.
4 Ensure that the target radio is turned on.
5 Ensure that the source radio is in cloning mode.
6 Ensure that the two radios are both from the same frequency band, same region and have the
same transmission power.
NOTE: The cloning cable is designed to operate only with compatible Motorola Solutions
SUC.
When ordering cloning cable kit, ensure to order the cloning cable kit with part number HKKN4026_.
For more information about the accessories, see
Accessories on page
47.
68012000044-ED
Chapter 5 : Radio Cloning
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Clp1010Clp1040Clp1060

Table of Contents