System Resources; Currently Allocated System Resources; Allocation Of System Resources - Siemens SIMATIC IPC427E Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC427E:
Table of Contents

Advertisement

Pin assignment for the PCIe-x4 card interface
23
24
25
26
27
28
29
30
31
32
8.6.3

System resources

8.6.3.1

Currently allocated system resources

All system resources (hardware addresses, memory configuration, allocation of interrupts,
DMA channels) are assigned dynamically by the Windows OS, depending on the hardware
configuration, drivers and connected external devices. You can view the current
configuration of system resources or possible conflicts with the following operating systems:
Windows 10
Windows Embedded Standard
Windows 7 Ultimate
8.6.3.2

Allocation of system resources

The following tables and images describe the system resources for the delivery state of the
device.
PCIe interrupt lines
The interrupts are assigned to devices by BIOS. Only non-shared interrupts are available for
the first Ethernet interface.
This means that applications or realtime operating system expansions can operate these
devices exclusively and with high-performance without having to share the interrupt with
other devices.
SIMATIC IPC427E
Operating Instructions, 02/2021, A5E37454814-AE
PETp2
Transmitter differential pair,
Lane2
PETn2
Transmitter differential pair,
Lane2
GND
Ground
GND
Ground
PETp3
Transmitter differential pair,
Lane3
PETn3
Transmitter differential pair,
Lane3
GND
Ground
RSVD
Reserved
PRSNT2#
Hot-plug presence detect
GND
Ground
Start menu "Start": Enter "msinfo32" in the search field and
press "Return" to confirm.
Technical specifications
8.6 Hardware descriptions
GND
Ground
GND
Ground
PERp2
Receiver differential
pair, Lane2
PERn2
Receiver differential
pair, Lane2
GND
Ground
Ground
PERp3
Receiver differential
pair, Lane3
PERn3
Receiver differential
pair, Lane3
GND
Ground
RSVD
Reserved
101

Advertisement

Table of Contents
loading