Usb 2.0 Pin Header; Usb 2.0 Port; System Resources; Currently Allocated System Resources - Siemens SIMATIC IPC327G Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC327G:
Table of Contents

Advertisement

7.5.3.3

USB 2.0 pin header

Pin
1
2
3
4
5
6
7
8
9
10
7.5.3.4

USB 2.0 port

Pin
1
2
3
4
7.5.4

System resources

7.5.4.1

Currently allocated system resources

Currently allocated system resources
All system resources (hardware addresses, memory utilization, interrupt assignment, DMA
channels) are assigned dynamically by the Windows operating system, depending on the
hardware equipment, drivers and connected external devices. You can view the current
allocation of system resources or possible conflicts in the Control Panel.
SIMATIC IPC327G
Operating Instructions, 09/2021, A5E51366275-AA
Signal
VBUS_USB1
VBUS_USB2
USB1_D-
USB2_D-
USB1_D+
USB2_D+
GND
GND
GND
GND
Short description
USB_P5V_fused (O)
USB_D0M (I/O)
USB_D0P (I/O)
USB_GND
Meaning
+5 V, fused
Data–
Data+
GND
Technical specifications
7.5 Hardware descriptions