Entrapment Protection Locations Continued
A monitored reversing edge (Type B2) or a monitored photo sensor (Type B1, see previous page) MUST be installed in EACH
entrapment area or operator WILL NOT function.
Monitored
Reversing
Edge
Mointored Reversing Edge Note:
Input is active in BOTH directions of gate travel.
See the 115 VAC control box Wiring/Owner's
manual OR Solar control box Wiring/Owner's
manual to wire entrapment protection devices.
OPTIONAL wireless transmitter can be used.
Receiver MUST monitor for the presence of the transmitter.
Greater than 4" but
less than 16"
16
Monitored Edge
Transmitter
OPTIONAL wireless transmitter can be used.
Receiver MUST monitor for the presence of the transmitter.
Typical Monitored Reversing Edge mounted on end of gate.
Note: If bottom edge of gate is less than 4" or
greater that 16" above the ground, then NO
reversing edge is required on bottom of gate.
If the distance between an entrapment or obstruction
exists less than 16" from the open gate, then
entrapment protection is REQUIRED for this area.
Monitored Edge
Transmitter
Typical Wireless Reversing
Edges mounted on bottom and
end of gate when needed.
If the bottom of gate is greater than 4"
but less than 16" above the ground
at any point in its arc of travel,
entrapment protection is REQUIRED
for this area.
4-Wire In-Line Edge
Reversing Edges are wired in series
Reversing Edge
Potential
Entrapment protection
Entrapment
Area
is RECOMMENDED for
this area.
2-Wire End-of-Line Edge
2-Wire
End-of-Line
Edge
Gate in Open Position
(Push to Open shown here)
6003-065-F-4-20