Address Space - Siemens SIMATIC ET 200eco PN M12-L Equipment Manual

Hide thumbs Also See for SIMATIC ET 200eco PN M12-L:
Table of Contents

Advertisement

PROFINET IO
4.1 Parameters/address space
Hardware interrupt on falling edge
Specifies whether a hardware interrupt is generated for a falling edge on the channel.
A hardware interrupt is only generated for the channel when there is a fault-free signal (value
status/QI = 1). This means no diagnostics is pending for the channel. See also: Address space
(Page 24)
4.1.3

Address space

The DI 16x24VDC M12‑L 8xM12 I/O device can be configured differently; see following table.
Depending on the configuration, additional/different addresses are assigned in the process
image input.
Configuration options of the DI 16x24VDC M12‑L 8xM12 I/O device
You can configure the I/O device Digital Inputs like this:
• With STEP 7 (TIA Portal)
• With GSD file in any configuration software
When you configure the I/O device by means of the GSD file, the configurations are available
under different short designations/device names in the device view of your configuration
software.
The following configurations are possible:
Table 4-2  Configuration options
Configuration
1 x 16-channel DI 16x24VDC
1 x 16-channel DI 16x24VDC QI
1 x 16-channel DI 16x24VDC MSI
Address space for configuration as 1 x 16-channel DI 16x24VDC
The following figure shows the address space allocation for the configuration as 16-channel
I/O device digital inputs without value status.
Figure 4-1  Address space for configuration as 1 x 16-channel DI 16x24VDC without value status
24
Short designation/
Configuration software, e.g., with STEP 7 (TIA Portal)
device name in the
Integrated in hardware
GSD file (device view
in the configuration
software)
DI 16x24VDC
DI 16x24VDC QI
DI 16x24VDC MSI
I/O device digital inputs DI 16x24VDC M12-L 8xM12 (6ES7141-6BH00-0BB0)
catalog STEP 7
(TIA Portal)
V16 or higher with HSP
0299
V16 or higher with HSP
0299
V16 or higher with HSP
0299
Equipment Manual, 03/2023, A5E46570510-AD
GSD file in
STEP 7 (TIA Portal) V11 or
higher or STEP 7 V5.5 SP4
HF1 or higher
X
X
X