General Data - YASKAWA VIPA 62H-MHC0 Manual

Hmi
Table of Contents

Advertisement

VIPA HMI

2.5 General data

Conformity and approval
Conformity
CE
Approval
UL
others
RoHS
Protection of persons and device protection
Type of protection
Electrical isolation
to the field bus
to the process level
Insulation resistance
Insulation voltage to reference earth
Inputs / outputs
Protective measures
Environmental conditions to EN 61131-2
Climatic
Storage / transport
Operation
Horizontal installation
Vertical installation
Air humidity
Pollution
Mechanical
Oscillation
Shock
Mounting conditions
Mounting place
Mounting position
HB160 | TP-ECO | 62H-MHC0 | en | 17-01
2014/35/EU
Low-voltage directive
2014/30/EU
EMC directive
Refer to Technical data
2011/65/EU
Restriction of the use of certain hazardous substances in
electrical and electronic equipment
-
IP20
-
electrically isolated
-
electrically isolated
-
-
AC / DC 50V, test voltage AC 500V
-
against short circuit
EN 60068-2-14
-20...+60°C
EN 61131-2
0...+50°C
EN 61131-2
0...+50°C
EN 60068-2-30
RH1 (without condensation, rel. humidity 10...95%)
EN 61131-2
Degree of pollution 2
EN 60068-2-6
1g, 9Hz ... 150Hz
EN 60068-2-27
15g, 11ms
-
In the control cabinet
-
Horizontal and vertical
Hardware description