YASKAWA VIPA 62H-MHC0 Manual page 31

Hmi
Table of Contents

Advertisement

VIPA HMI
Autostart
HB160 | TP-ECO | 62H-MHC0 | en | 17-01
With [Search Image] a list of all the firmware images is shown, which are available on the
panel and connected storage media. These images will be listed with create data and
version number. Choose your new image.
If the selected image is not correct for your panel, an error massage will appear. If the
image is correct for your panel, in the following message the current installed image ver-
sion and the new selected image version will be listed.
1.
Click on [Update Image] to execute the update. This can take a few seconds.
2.
In the following window click on [Finish] to end the update.
ð Then the display gets dark.
3.
Switch the power supply off the panel off and on.
ð After the restart the calibration window is opened.
4.
Re-calibrate the panel as described. After calibration tap anywhere on the screen.
ð The calibration window will be closed.
5.
Via 'Start è Settings è Control Panel' start the program AutoRunMaker.
Ä Chapter 3.4 'Installation Movicon and Startup-Manager' on page 33
With [Autostart] you define which runtime and which project will be started automatically
together with the panel startup.
With [...] under "Runtime path" res. "Project path" all existing runtimes res. projects on the
panel and the storage media are listed.
Under "Delay Time" you can adjust a delay time > 0 by using the buttons [+] and [-]. 5
seconds are default.
Deployment under Windows CE 6.0 Core
Commissioning > VIPA Startup-Manager
31