YASKAWA VIPA 62P-PNJ0 Series Manual

YASKAWA VIPA 62P-PNJ0 Series Manual

Hide thumbs Also See for VIPA 62P-PNJ0 Series:

Advertisement

Quick Links

VIPA HMI Panel PC
PPC | 62P-PNJ0 | Manual
HB160 | PPC | 62P-PNJ0 | GB | 14-36

Advertisement

Table of Contents
loading

Summary of Contents for YASKAWA VIPA 62P-PNJ0 Series

  • Page 1 VIPA HMI Panel PC PPC | 62P-PNJ0 | Manual HB160 | PPC | 62P-PNJ0 | GB | 14-36...
  • Page 2 VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: +49 9132 744-0 Fax: +49 9132 744-1864 email: info@vipa.com Internet: www.vipa.com 67P-PNJ0_000_PPC015CE,1,GB - © 2014...
  • Page 3: Table Of Contents

    VIPA HMI Panel PC Table of contents Table of contents General..................4 1.1 Copyright © VIPA GmbH ........... 4 1.2 About this manual.............. 5 1.3 Safety information.............. 6 Hardware description.............. 8 2.1 Safety information for users..........8 2.2 Properties................9 2.3 Structure................
  • Page 4: General

    General VIPA HMI Panel PC Copyright © VIPA GmbH General 1.1 Copyright © VIPA GmbH All Rights Reserved This document contains proprietary information of VIPA and is not to be disclosed or used except in accordance with applicable agree- ments. This material is protected by the copyright laws.
  • Page 5: About This Manual

    VIPA HMI Panel PC General About this manual Trademarks VIPA, SLIO, System 100V, System 200V, System 300V, System 300S, System 400V, System 500S and Commander Compact are registered trademarks of VIPA Gesellschaft für Visualisierung und Prozessautomatisierung mbH. SPEED7 is a registered trademark of profichip GmbH. SIMATIC, STEP, SINEC, TIA Portal, S7-300 and S7-400 are regis- tered trademarks of Siemens AG.
  • Page 6: Safety Information

    General VIPA HMI Panel PC Safety information Guide to the document The following guides are available in the manual: An overall table of contents at the beginning of the manual References with page numbers Availability The manual is available in: printed form, on paper in electronic form as PDF-file (Adobe Acrobat Reader) Icons Headings...
  • Page 7 VIPA HMI Panel PC General Safety information CAUTION! The following conditions must be met before using or commissioning the components described in this manual: – Hardware modifications to the process control system should only be carried out when the system has been disconnected from power! –...
  • Page 8: Hardware Description

    Hardware description VIPA HMI Panel PC Safety information for users Hardware description 2.1 Safety information for users Handling of electro- VIPA modules make use of highly integrated components in MOS- static sensitive modules Technology. These components are extremely sensitive to over-vol- tages that can occur during electrostatic discharges.
  • Page 9: Properties

    VIPA HMI Panel PC Hardware description Properties 2.2 Properties General The VIPA Panel PC is a combination of industrial PC with state of the art performance features and a touch panel with ideal display capabil- ities. The Panel PC is a compact and modular embedded PC based Ò...
  • Page 10: Structure

    Hardware description VIPA HMI Panel PC Structure > Overview 2.3 Structure 2.3.1 Overview Front view Slot for voltage supply (DC 12-30V) VGA interface Reset button RS232/RS422/RS485 interface COM 2 RS232/RS422/RS485 interface COM 1 4x"Host"-USB-A interface RJ45 jack for Ethernet communication LAN 2 RJ45 jack for Ethernet communication LAN 1 3.5mm Audio Line out 10 Power switch (pushbutton)
  • Page 11 VIPA HMI Panel PC Hardware description Structure > Overview Bottom view 1 Slot for voltage supply (DC 12-30V) 2 VGA interface 3 Reset button 4 RS232/RS422/RS485 interface COM 2 5 RS232/RS422/RS485 interface COM 1 6 4x"Host"-USB-A interface 7 RJ45-Buchse for Ethernet communication LAN 2 8 RJ45-Buchse for Ethernet communication LAN 1 9 3.5mm Audio Line out Please make sure that the Panel PC always has to be...
  • Page 12: Interfaces

    Hardware description VIPA HMI Panel PC Structure > Interfaces 2.3.2 Interfaces RS232/RS422/RS485 The 9-pin male SubD connector may be switched in the BIOS. Here interface (switchable) also the termination resistor of the RS422 and RS485 interface may be activated or deactivated. Ä...
  • Page 13 VIPA HMI Panel PC Hardware description Structure > Interfaces HB160 | PPC | 62P-PNJ0 | GB | 14-36...
  • Page 14: Memory Management

    Hardware description VIPA HMI Panel PC Structure > Memory management VGA interface VGA SubD HD15 jack to connect a second display. Line out 3.5 mm stereo jack to connect an active speaker system or an ear- phone. "Host"-USB-A Using the "Host"-USB-A interface USB mouse, keyboard, stick or USB hard discs can be connected.
  • Page 15: Dimensions

    VIPA HMI Panel PC Hardware description Dimensions Slot for CFast At the back of the Panel PC there is a card slot for a memory card. At this slot you can plug storage modules of the type CFast 2.0 - 600 MB/s (6GBit/s) - SATA protocol - not hot-swap compatible.
  • Page 16 Hardware description VIPA HMI Panel PC Dimensions 15.6" - 67P-PNJ0-... Front panel thickness 3 ... 12mm Installation cutting (W x H) 401 x 296mm Front panel (W x H x T) 417.80 x 312.80 x 6.20mm Rear panel (W x H x D) 396 x 291 x 57.60mm Installation depth 57.60mm...
  • Page 17: General Data

    VIPA HMI Panel PC Hardware description General data 2.5 General data Conformity and approval Conformity 2006/95/EG Low-voltage directive 2004/108/EG EMC directive Approval UL 508 Approval for USA and Canada others RoHS 2011/65/EU Product is lead-free; Restriction of the use of certain hazardous substances in electrical and electronic equipment Protection of persons and device protection...
  • Page 18: Technical Data

    Hardware description VIPA HMI Panel PC Technical data Mounting conditions Mounting place In the control cabinet Mounting position Horizontal and vertical Standard Comment Emitted interfer- EN 61000-6-4 Class A (Industrial area) ence Noise immunity EN 61000-6-2 Industrial area zone B EN 61000-4-2 8kV at air discharge (degree of severity 3), 4kV at contact discharge (degree of severity...
  • Page 19 VIPA HMI Panel PC Hardware description Technical data Order no. 67P-PNJ0-EB User software Movicon 11 CE Standard Work memory 2 GB User memory 2 GB Available memory (user data) 1200 MB SD/MMC Slot CF Card Slot Typ II CFast Slot ü...
  • Page 20 Hardware description VIPA HMI Panel PC Technical data Order no. 67P-PNJ0-EB Technical data power supply Power supply (rated value) DC 24 V Power supply (permitted range) DC 20.4...28.8 V Reverse polarity protection ü Current consumption (no-load operation) 1.2 A Current consumption (rated value) 1.3 A Inrush current 1.3 A...
  • Page 21: Deployment Panel Pc

    VIPA HMI Panel PC Deployment Panel PC Installation Deployment Panel PC 3.1 Installation Overview The Panel PC is suitable for the installation in operating tables and control cabinet fronts. The installation happens via the back. The Panel PC is provided with a fixing technique with not losable screws that allows an easy connection with a crosstip screwdriver.
  • Page 22: Installation Of The Cfast Card

    Deployment Panel PC VIPA HMI Panel PC Installation of the CFast card Connect power supply For the cabling of the power supply DC 12-30V a green plug is used. The connector is a plug with screw contacts. The plug has the fol- lowing assignment: DC 24V DC 0V...
  • Page 23: Commissioning

    VIPA HMI Panel PC Deployment Panel PC Commissioning > VIPA Startup-Manager 3.3 Commissioning CAUTION! – Before commissioning the device must be brought to room temperature. – At condensation the device must be absolutely dry before connected to power. – To avoid overheat during operation the device must not be laid open to direct sun light.
  • Page 24 Deployment Panel PC VIPA HMI Panel PC Commissioning > VIPA Startup-Manager Backup Exit Back Settings In [Settings] under Change Settings you can set a password for the Startup-Manager. The password will be requested when interrupting the start countdown. By default, no password is defined. In [Settings] the system settings can be set exactly like via Windows ‘Start è...
  • Page 25 VIPA HMI Panel PC Deployment Panel PC Commissioning > VIPA Startup-Manager At "Delay Time" you can adjust a delay time > 0 by using the buttons [+] and [-]. 5 seconds are default. Via "Program start" with [+] you can add programmes, which have to start automatically.
  • Page 26: Connection To A Plc System

    Deployment Panel PC VIPA HMI Panel PC Operating system Windows Embedded Compact 7 > General 3.4 Connection to a PLC system Overview For the inclusion into your PLC system several HMI/SCADA project- engineering platforms are at your disposal that has to be installed on an external PC.
  • Page 27 VIPA HMI Panel PC Deployment Panel PC Operating system Windows Embedded Compact 7 > General Differences to the Please regard that for the deployment of WEC7 a thorough knowl- Ò Ò standard Windows edge of operating Windows are assumed. Here are only shown the operation Ò...
  • Page 28: Structure

    Deployment Panel PC VIPA HMI Panel PC Operating system Windows Embedded Compact 7 > Structure 3.5.2 Structure Icon Via icons on the desktop you gain direct access to the application related to the icon. Desktop Ò The desktop is the screen that is shown after login to Windows It contains e.g.
  • Page 29 VIPA HMI Panel PC Deployment Panel PC Operating system Windows Embedded Compact 7 > Structure Show desktop All windows are minimized and the desktop is shown. Software keyboard This button displays a keyboard at the screen. "Hide Input Panel" hides the keyboard again. Software keyboard The button allows you to select one of the available software key-...
  • Page 30: Integrated Server

    Deployment Panel PC VIPA HMI Panel PC Integrated server > General System setting (Control As many components of the Control Panel conform with the System Panel) Ò Control of Windows , most of the description is not necessary. The description of the control panel components relevant for operating the Panel PC can be found in the following: Set Display Via ‘Start è...
  • Page 31: Ftp Server

    VIPA HMI Panel PC Deployment Panel PC Integrated server > ftp server Server A server is an application that waits for the contact request of a client application and exchanges messages with it after contact start. This communication type is called Client-Server communication. Host Computer within a network where at least one server is running.
  • Page 32: Telnet Server

    Deployment Panel PC VIPA HMI Panel PC Integrated server > Telnet server As soon as your Panel PC is connected via Ethernet, you can monitor the IP address data via in the taskbar. After you’ve confirmed the pre-settings, start your ftp client (e.g. Windows Explorer) and enter the following text into the "address bar": ftp://wince:vipatp@IP-Adresse...
  • Page 33: Vnc Server

    VIPA HMI Panel PC Deployment Panel PC Integrated server > VNC server Enter the following: Login: wince Password: vipatp (entry is hidden) ð After entering valid user data a command line for entries appears: By entering Exit res. closing the window you can terminate the Telnet connection at any time.
  • Page 34 Deployment Panel PC VIPA HMI Panel PC Integrated server > VNC server Because you can deactivate all safety attitudes with the VNC server, you should use these exclusively for start-up! For this reason the VNC server is on delivery deactivated. Due to software reasons VIPA does not support the VNC server function! Establishing a VNC con-...
  • Page 35: Access To The Network Resources

    VIPA HMI Panel PC Deployment Panel PC Access to the network resources 3.7 Access to the network resources Overview The Panel PC allows you to access shared resources in a Microsoft network like drives and printer. Here you may assign existing public directories or printer in the network to local directories or printer in the Panel PC.
  • Page 36: Bios Setup

    BIOS setup VIPA HMI Panel PC Overview BIOS setup 4.1 Overview In this chapter you will find information, required for calling the BIOS setup and the possible settings. The BIOS (Basic Input and Output System) setup program is a menu driven utility that enables you to make changes to the system configu- ration and tailor your system to suit your individual work needs.
  • Page 37: Main

    VIPA HMI Panel PC BIOS setup Main Selection boot medium Powering on the computer and immediately pressing [F7] allows you, as long as the loading screen is shown, to change to the boot medium selection. Legends Function ßà Moves the highlight left or right to select a menu áâ...
  • Page 38: Advanced

    BIOS setup VIPA HMI Panel PC Advanced Intel RC Version Display the Intel Reference Code version. System Date The date format is day month/date/year an. Day displays a day, from Monday to Sunday. Month displays the month, from January to December. Date displays the date, from 1 to 31.
  • Page 39 VIPA HMI Panel PC BIOS setup Advanced Launch LAN1/2 PXE Enables or disables the boot option for legacy network devices con- OpROM nected to LAN1 and LAN2. Disabled - Starts no PXE OpROM Enabled - Starts the PXE OpROM, to be able to boot about PXE Submenu "CPU Config- This section is used to configure the CPU.
  • Page 40 BIOS setup VIPA HMI Panel PC Advanced Limit CPUID Maximum The CPUID instruction of some newer CPUs will return a value greater than 3. The default is disabled because this problem does not exist in the Windows series operating systems. If you are using an operating system other than Windows, this problem may occur.
  • Page 41 VIPA HMI Panel PC BIOS setup Advanced Legacy USB Support Due to the limited space of the BIOS ROM, the support for legacy USB keyboard (in DOS mode) is by default set to disabled. With more BIOS ROM space available, it will be able to support more advanced features as well as provide compatibility to a wide variety of periph- eral devices.
  • Page 42 BIOS setup VIPA HMI Panel PC Advanced Serial Port Enables or disables the serial port. Disabled - Serial port is not available Enabled - Serial port is available Change Settings Selects an optimal setting for the super IO device. Onboard Serial Port 0 This field is used to configure the mode of serial port 0 as RS232, Mode RS422, RS485 or RS485 AUTO.
  • Page 43: Chipset

    VIPA HMI Panel PC BIOS setup Chipset 4.4 Chipset This section is used to configure the system based on the specific features of the chipset. CAUTION! Setting incorrect field values may cause the system to malfunction. Host Bridge Display the memory information. Ò...
  • Page 44 BIOS setup VIPA HMI Panel PC Chipset IGFX-Boot Type This field is used to configure which video device will be activated during POST. This has no effect if external graphics present. The options are CRT, LVDS, DP-LVDS + CRT. Backlight Control Select The available options are ‘Pyroelectric sensor’...
  • Page 45: Boot

    VIPA HMI Panel PC BIOS setup Boot Fixed Graphics Memory This field is used to configure the memory size of the fixed graphics, Size the options are 128MB and 256MB. Submenu "South This field is used to configure the south bridge chipset. Bridge"...
  • Page 46: Security

    BIOS setup VIPA HMI Panel PC Security Setup Promt Timeout This section configures the number of seconds to wait for the setup activation key. Bootup NumLock State This allows you to determine the default state of the numeric keypad. On - (default) The function of the numeric keypad is the number keys.
  • Page 47: Save And Exit

    VIPA HMI Panel PC BIOS setup Save and exit If ONLY the User's If only the User's password is set, then this is a power on password password is set and must be entered to boot or enter setup. In Setup the user will have administrator rights.
  • Page 48 BIOS setup VIPA HMI Panel PC Save and exit Discard Changes and To exit the Setup utility without saving the changes, select this field Exit then press [Enter]. You may be prompted to confirm again before exiting. The BIOS setup exits and the POST continued. You can also press [Esc] to exit without saving the changes.
  • Page 49: Installation Guidelines

    VIPA HMI Panel PC Installation guidelines Basic rules for the EMC-equitable assembly of installations Installation guidelines 5.1 Basic rules for the EMC-equitable assembly of installations General The installation guidelines contain information about the interference free deployment of a PLC system. There is the description of the ways, interference may occur in your PLC, how you can make sure the electromagnetic compatibility (EMC), and how you manage the isolation.
  • Page 50 Installation guidelines VIPA HMI Panel PC Basic rules for the EMC-equitable assembly of installations Coupling mechanisms The following table shows the four different coupling mechanisms, and interference their causes and possible interference sources. sources Coupling mechanism Cause Typical source Galvanic coupling Galvanic or metallic coupling Pulsed devices (Net influ- always occurs, when two cur-...
  • Page 51: Emc-Equitable Assembly

    VIPA HMI Panel PC Installation guidelines EMC-equitable assembly Basic rules for EMC In the most times it is enough to take care of some elementary rules to guarantee the EMC. Please regard the following basic rules when installing your PLC. Take care of a correct area-wide grounding of the inactive metal parts when installing your components.
  • Page 52: Emc-Equitable Cabling

    Installation guidelines VIPA HMI Panel PC EMC-equitable cabling Grounding means the conducting connection of all inactive metal parts. The sum of all interconnected inactive parts is called ground. Inactive parts are all conductive parts electrically separated from all active parts by means of a basic isolation and that may only get voltage in case of an error.
  • Page 53 VIPA HMI Panel PC Installation guidelines EMC-equitable cabling Group A Group B Group C Group D Group A Group B Group C Group D The lines may be installed in common bundles or cable trusses. The lines have to be installed in different bundles or cable trusses (without min.
  • Page 54 Installation guidelines VIPA HMI Panel PC EMC-equitable cabling Equipotential bonding Potential differences can occur between different sections when con- trollers and peripheral equipment are connected by means of non-iso- lated connections or the screens of screened cables are connected at both ends and grounded on different sections of the plant.
  • Page 55: Special Precautions Providing High Noise Immunity

    VIPA HMI Panel PC Installation guidelines Special precautions providing high noise immunity You should always use metallic or metalized covers for serial data lines. Connect the screen of the data line to the cover. Do not con- nect the screen to PIN 1 of the connector! In case of stationary opera- tions it is recommended that the remove the insulation from the screened cable without cutting the screen and to attach this point to the screening/neutral rail.
  • Page 56 Installation guidelines VIPA HMI Panel PC Special precautions providing high noise immunity Connections of DC-activated Connections of AC-activated inductors inductors using a diode using a Z-diode using a varistor using RC-net- work Power outlet for PGs Every cubicle must be provided with a power outlet for the PU. These outlets must be wired to the distribution system, which is also used to connect the neutral conductor for the cubicle.
  • Page 57: Checklist For The Emc-Compliant Installation Of Controllers

    VIPA HMI Panel PC Installation guidelines Checklist for the EMC-compliant installation of controllers 5.5 Checklist for the EMC-compliant installation of controllers EMV-measures Space for Notes Connection of the inactive parts You should take special care to check the connections of: Module racks Frames Screen and protected earth conductor...

This manual is also suitable for:

Ppc015 ce

Table of Contents