120 en | Troubleshooting
11.2

Resolving problems

The following table is intended to help identify the causes of
malfunctions and correct them where possible.
Malfunction
No image
transmission to
remote location.
No connection
established, no
image transmission.
AR18-10-B006 | v1.1 | 2010.06
This manual downloaded from http://www.manualowl.com
Possible causes
Defective camera.
Faulty cable connections. Check all cables, plugs,
Incorrect encoder stream
property set for
connection to hardware
decoder.
The unit's configuration.
Faulty installation.
Wrong IP address.
Faulty data transmission
within the LAN.
The maximum number of
connections has been
reached.
Installation and Operation Manual
Dinion2X IP Camera
Solution
Connect a local monitor
to the camera and check
the camera function.
contacts and
connections.
Select the H.264 BP+
(HW decoder) option on
the Encoder Streams
configuration page.
Check all configuration
parameters.
Check all cables, plugs,
contacts and
connections.
Check the IP addresses
(terminal program).
Check the data
transmission with ping.
Wait until there is a free
connection and call the
transmitter again.