If not avoided, this could result in property damage or risk of damage to the unit. NOTICE! This symbol indicates information or a company policy that relates directly or indirectly to the safety of personnel or protection of property. Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01...
Overloading - Do not overload circuits. This can cause fire or electrical shock. Power cable protection - Protect the power cable from foot traffic, from being pinched by items placed upon it, and at cable's exit from the unit. | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc.
Page 7
– unit has been dropped; – unit exhibits a distinct change in performance; – unit does not operate normally when the user correctly follows the operating instructions. Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01...
Page 8
15. Attachments, changes or modifications - Only use attachments/accessories specified by the manufacturer. Any change or modification of the equipment, not expressly approved by Bosch, could void the warranty or, in the case of an authorization agreement, authority to operate the equipment.
Risk Group 1 sources do not pose an infrared radiation hazard for the eye for times less than 100 s at distances beyond 200 mm or 8 inches. Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01...
Page 10
Disposal - Your Bosch product was developed and manufactured with high-quality material and components that can be recycled and reused. This symbol means that electronic...
Page 11
DINION capture 5000/7000 Safety | en Environmental statement - Bosch has a strong commitment towards the environment. This unit has been designed to respect the environment as much as possible. Electrostatic-sensitive device - Use proper CMOS/MOS-FET handling precautions to avoid electrostatic discharge.
Page 12
(SELV) circuits. SELV circuits should only be connected to other SELV circuits. Because ISDN circuits are treated like telephone-network voltage, avoid connecting the SELV circuit to the Telephone Network Voltage (TNV) circuits. | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc.
Informations FCC et ICES (modèles utilisés aux États-Unis et au Canada uniquement) Ce produit est conforme aux normes FCC partie 15. la mise en service est soumises aux deux conditions suivantes : Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01...
Page 14
États-Unis, sous la référence n° 004-000-00345-4. NOTICE! This is a class A product. In a domestic environment this product may cause radio interference, in which case the user may be required to take adequate measures. | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc.
Bosch notices Video loss Video loss is inherent to digital video recording; therefore, Bosch Security Systems cannot be held liable for any damage that results from missing video information. To minimize the risk of lost digital information, Bosch Security Systems recommends multiple, redundant recording systems, and a procedure to back up all analog and digital information.
2.8 x 2.1 m (PAL units) 6 ft 6 in. x 4 ft 11 in. (NTSC units) Overview Camera (DINION capture 7000): Approximately twice the distance of the License Plate Camera. Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01...
For maximum performance ensure the mounting angle is as narrow as possible. To capture vehicle speeds up to 225 km/h (140 mph) the horizontal and vertical mounting angle should be less than 30°. | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc.
Page 19
If the imager is too close to the license plate, the plate could disappear from the field of view before it is captured. Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01...
A stud/bolt diameter of 6.0 mm (or 1/4 inch) able to withstand a 300 kg (660 lb) pull-out force is recommended. The mounting material must be able to withstand this pull out force. | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc.
Page 21
5 mm hex key. Place the license plate camera at the desired pan angle and tighten the bolt. Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01...
Page 22
2.5 in. screw with washer securely into the stud. – Follow this procedure to attach the three remaining screws. NOTICE! The camera has not been evaluated for safety requirements using other mounting kits. | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc.
A UTP adapter (VDA-455UTP) is available as an optional accessory to allow a UTP video cable to be connected to the BNC connector. Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01...
Automatic Mode Switching is inactive by default and requires setup to operate as desired. In most conditions, Automatic Mode Switching may not be necessary. Activate the switch only if the license plate camera | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc.
Page 25
Important: After changes are made to any settings ensure the DINION capture is left in mode 1 under 'Mode' in the Main menu (refer to Section 4.1 Menus, page 28). Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01...
Page 26
Lower the fixed gain setting until the desired image is achieved. If the lowest gain setting is reached and the image is still too bright try changing the shutter to 1/10000. | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc.
Page 27
1/5000 from the factory and should be changed only by an experienced user. Changing the shutter speed affects maximum capture speed of the vehicle and ambient rejection ability. Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01...
(center) for longer than 2 seconds. 4.1.2 Accessing Menu Keys Five keys, located behind the rear panel of the license plate camera and the overview camera, are used for navigating through the menu system. | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc.
Page 29
Remove the four (4) hex socket screws from the back panel using the supplied 3 mm hex key. Locate the keypad inside the imager. Up key Right key Down key Left key Menu/Select key Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01...
Page 30
Remove the hex socket screw from the back panel using the supplied 3 mm hex key. Locate the keypad inside the imager. Up key Right key Down key Left key Menu/Select key | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc.
Default installation mode to provide stable pictures over a 24-hour period. These settings are optimized for out-of- the-box installation. FullSun (Mode 2) Reduced gain to provide properly exposed image during bright conditions. Mode 3 Default settings. Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01...
There are four different methods of controlling the IR filter: – via an alarm input, – via Bilinx communication, – automatically, based on the observed light levels, or – as part of the programmable mode profile. | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc.
Bilinx communications can only be disabled using the buttons on the camera. Disabled camera buttons When the Bilinx communications link is active, the buttons on the camera are disabled. Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01...
DINION capture 7000 only. The license plate camera is pre-configured to operate in a fixed exposure mode, therefore ALC, Peak average, and Speed settings have no impact. Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01...
Page 36
DVR or IP encoder to compensate for compression methods. Off - The camera output is optimized for connection to an analog system (matrix switcher or monitor). EXIT Returns to main menu. | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc.
5000, 1/10K the shutter speed to 1/10000 to darken the image or decrease the shutter speed to 1/2000 or more to brighten the image, however the maximum capture speed is reduced. Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01...
Page 38
When active, some noise or spots may appear in the picture. This is normal camera behavior. It may also cause motion blur on moving objects. EXIT Returns to main menu. | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc.
Motion - the camera avoids motion blur as long as the light level permits (it switches to monochrome earlier than it would with Color priority). Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01...
Page 40
(mono) is switched Off in monochrome mode. On - the color burst remains active even in monochrome mode (required by some DVRs and IP encoders). EXIT Returns to main menu. | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc.
Autoblack On, Off Autoblack On automatically increases the visibility of details even when scene contrast is less than full-range due to mist, fog, etc. Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01...
Page 42
This issue can be corrected by selecting Off. Peak White On, Off Use Peak White Invert to reduce glare Invert from the CRT/LCD display. Use this setting with discretion. EXIT Returns to main menu. | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc.
Manual - adjusts the Blue gain. Green gain -50 to +50 Manual - adjusts the Green gain. Saturation -15 to +5 Adjusts the color saturation. -15 gives a monochrome image. EXIT Returns to main menu. Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01...
Select key moves the flashing cursor to the opposite corner, which can now be moved. Pressing Select again freezes the area and exits the area menu. There is one programmable VMD area. | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc.
Connections Submenu Connection parameters Test signals Submenu Test patterns and texts Camera ID Submenu Select to access ID submenu Defaults Submenu Returns all settings for all modes to factory defaults Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01...
Manual, DC-iris, Video modes: select the matching lens type to force the camera to the correct lens mode. Detected Shows the type of lens detected when auto lens detection is used. | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc.
Automatic Mode Switching for the Mono license plate camera, default is Mode In the overview camera on DINION capture 7000 models, selects the operating mode of the camera when the alarm input is active. Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01...
Coax12 coaxial connections up to 1000 m (3000 ft). For optimum results select the coaxial cable type used or, if unknown, select default. | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc.
Test pattern Color bars Select the desired test pattern to help 100%, installation and fault-finding. Grayscale 11-step, Sawtooth 2H, Checker board, Cross hatch, UV plane EXIT Returns to Install menu. Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01...
Ticker bars On, Off The ticker bar moves continuously to show that the image is live and not frozen or played back. EXIT Returns to Install menu. | 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc.
Restores all settings of the six modes to their default (factory) values. Select YES then press the Menu/Select button to restore all values. When completed the message RESTORED! is shown. Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01...