18 | Elisa
Emilie
TM

Troubleshooting

UK
Problem
Water
Leaks
Water is
only fully
hot OR fully
cold
Installation Guide
and Rosa
TM
TM
Solution
b
If the Aquahu
leaks could occur down or within the wall.
*Turn off the mains water supply*
Fully close the built in service valves, make sure the servicing valves are
tightened securely into the aquahu
Check all inlets and outlets have been fitted with ptfe tape.
Check all headwork O'Rings are installed correctly and not perished.
Check blanking plugs have been applied to the correct/un-used outlets
Check the thermostatic cartridge and diverter
cartridge/valves are secure.
Check outlet plumbing.
Perform pressure and leak testing - refer to Aquahub
guide (stage 1 installation).
If the inlets have been plumbed in incorrectly, the shower will only
dispense fully hot OR fully cold water. Despite turning the temperature
dial, the water will not blend to a showering temperature.
You have probably plumbed the water
supplies into the wrong inlets.
This can be easily corrected by installing
the headworks upside-down (so the 'H'
and 'C' are on the bottom) see page 9.
Now the inlets have been switched and
your thermostatic cartridge should work
correctly.
or headworks have been incorrectly installed,
TM
b
.
TM
installation
TM
Incorrect

Advertisement