Maintenance

UK
Regular Maintenance
Remove and clean the control dials to remove any build-up of limescale etc.
Ensure the temperature override pin depresses easily and is clear of
any deposits.
Thoroughly clean the faceplate and ensure the drainage channel underneath is
open and free of residue.
Annual Maintenance
Isolate all water supplies to your shower.
Remove and thoroughly clean the control dials
and faceplate.
Remove the headworks and filters within, flush with
hot water and clean before reinstalling. Extract the
cartridge and valve, clean the water channels and
cavities with a small brush, checking for any signs
of limescale build up etc and clean until removed.
Soaking the cartridge/valve in white vinegar for
60 minutes will help remove the limescale. Rinse
thoroughly once soaked and check all O'rings are
non-perished/located correctly before reinstalling
the headworks and cartridge.
Turn the isolation valves to ensure they are not
stuck in position and return to fully open.
Clean the plastic Aquahub
there is no mineral build up at the bottom.
Re-install the faceplate and dials according to the
installation guide steps.
Open the water supplies and check the shower is
working proficiently.