20 | Elisa
Emilie
TM
Troubleshooting
UK
Problem
Buttons not
working
Faceplate
not sitting
flush with
the wall
Installation Guide
and Rosa
TM
TM
Solution
If the wrong extension bosses have been screwed on, the buttons will
not fully depress or disengage the valves behind.
Remove the faceplate and
compression plate.
Unscrew the black extension bosses and
replace with the longer spare set.
(see page 8).
Readjust them to the correct depth using
the metal bracket. (see page 11).
You may have incorrectly installed the Aquahu
extension bosses or compression plate, which will prevent the
faceplate from sitting flush with the wall.
Check the compression plate is sitting flush
with the tiles. If not, remove it and check the
plastic shroud behind has been trimmed
flush to the wall ( It should not protrude
more than 2-3mm past the finished wall
surface). If the shroud seems ok, make sure
the compression plate is located on the
shroud correctly and is screwed down tight
against the wall.
Lastly, if this has not corrected the problem,
it is likely that you have installed the wrong
button extension bosses. Unscrew them
and replace with the shorter set. Then
readjust using the metal bracket supplied.
(see page 11).
70-80mm depth
60-70mm depth
Blank headworks
b
shroud, button