Leak Testing - Outback Meteor 3 Assembly And Operating Instructions Manual

Table of Contents

Advertisement

2
1
1. Maximum diameter or breadth is 320mm.
2. Maximum height (regulator included) is 700mm.
PROCEED TO THE NEXT PAGE FOR INSTRUCTIONS ON OPERATION AND MAINTENANCE
ALL JOINTS AND CONNECTIONS MUST NOW BE LEAK TESTED BEFORE USING THE
Leak test annually, and whenever the gas bottle is removed or replaced.
Always perform a leak test in a well-ventilated area.
Step 1 - Confirm all control knobs are in the off position.
Step 2 - Turn the gas on / open the gas control valve on the gas bottle or regulator.
Step 3 - Check for leaks by brushing a solution of ½ water and ½ liquid detergent / soap over all the
gas system joints, including gas bottle valve connections, hose connections, and regulator
connections.
Step 4 - NEVER USE AN OPEN FLAME to test for leaks at any time.
Step 5 - If bubbles form over any of the joints there is a leak
Turn off the gas supply at the gas bottle
Retighten all joints
Repeat test
If bubbles form again do not use the barbecue and contact your local distributor for assistance.
Always wipe the mixed solution (½ water and ½ liquid detergent / soap) from all joints and
connections after leak testing.
Leak Test Diagram
ASSEMBLY IS NOW COMPLETE.
BARBECUE.

Leak Testing

12

Advertisement

Table of Contents
loading

Table of Contents