Chapter 4: Nvme Expansion Enclosure Service Procedures; Add A Drive In An Nvme Expansion Enclosure; Removing The Front Bezel - Dell PowerStore 1000 Installation And Service Manual

Table of Contents

Advertisement

The NVMe expansion enclosure contains customer-replaceable components. Follow these procedures to safely replace a failed
component.
NOTE:
Review the information in
Topics:

Add a drive in an NVMe expansion enclosure

Replace a faulted drive in an NVMe expansion enclosure
Replace a power supply module in an NVMe expansion enclosure
Replace a fan module in an NVMe expansion enclosure
Replace a Clock Distribution Board in an NVMe expansion enclosure
Replace an Access Module in an NVMe expansion enclosure
Replace a data interface board in an NVMe expansion enclosure
Replace a dual inline memory module (DIMM)
Add a drive in an NVMe expansion enclosure
Take the following actions to add a new drive to an NVMe expansion enclosure.

Removing the front bezel

About this task
NOTE:
Remove the front bezel of the expansion enclosure to gain access to the drives. The bezel is required for EMI
compliance when the enclosure is powered up. Remove it only to replace or add a drive.
Steps
1. If the bezel has a lock, insert the key that shipped with your enclosure into the lock, and turn the key to unlock the bezel.
2. Press the two latch buttons on the bezel surface to release the bezel from the cabinet.
3. Pull the bezel off the cabinet, and put it on a clean, static-free surface.
140
NVMe expansion enclosure service procedures
NVMe expansion enclosure service
Safety precautions for handling replaceable units
procedures
before handling replaceable parts.