SAS expansion enclosure service procedures
The SAS expansion enclosure contains customer-replaceable components. Follow these procedures to safely replace a failed
component.
NOTE:
Review the information in
Topics:
•
Add a drive in a SAS expansion enclosure
•
Replace a faulted drive in a SAS expansion enclosure
•
Replace a link control card in a SAS expansion enclosure
•
Replace a power/cooling module in a SAS expansion enclosure
Add a drive in a SAS expansion enclosure
Take the following actions to add a new drive to a SAS expansion enclosure.
Removing the front bezel
About this task
NOTE:
Remove the front bezel of the expansion enclosure to gain access to the drives. The bezel is required for EMI
compliance when the enclosure is powered up. Remove it only to replace or add a drive.
Steps
1. If the bezel has a lock, insert the key that shipped with your enclosure into the lock, and turn the key to unlock the bezel.
2. Press the two latch buttons on the bezel surface to release the bezel from the cabinet.
3. Pull the bezel off the cabinet, and put it on a clean, static-free surface.
Figure 150. Removing the front bezel
124
SAS expansion enclosure service procedures
Safety precautions for handling replaceable units
before handling replaceable parts.
CL5261