Identify A Faulted Power Supply From Powerstore Manager; Base Enclosure Power Supply Leds; Remove A Power Supply - Dell PowerStore 1000 Installation And Service Manual

Table of Contents

Advertisement

Identify a faulted power supply from PowerStore Manager

Before you replace a power supply, ensure that you have identified its location within the system. Using PowerStore Manager,
you can identify and locate a faulted power supply.
Steps
1. From PowerStore Manager, select Hardware.
2. Select the appliance that includes the power supply that you need to replace.
3. On the Components card, under Rear View, expand BaseEnclosure.
4. Expand the node that includes the power supply, and then select PSU0.
Faulted parts appear in red in the image of the system, and report a status of Faulted in the State field.

Base enclosure power supply LEDs

Use the fault LEDs to identify the faulted part.
Figure 52. Base enclosure power supply LEDs
Table 3. Base enclosure AC power supply LEDs
LED
Fault
Supply output status
AC power (input)

Remove a power supply

About this task
There are two power supplies. The power supplies are installed in the top and bottom nodes, and the top power supply is
installed upside-down. This procedure works for removing either power supply, however, the direction in which the retention bail
and release handle are pressed is reversed for the upside-down power supply.
NOTE:
You do not need to power down the system to remove a power supply.
Steps
1. Rotate the power cable retention bail to the left (to the right for the upside-down power supply). Remove the power cable
from the power supply.
Location
State
Solid amber
Off
Green
Off
Green
Off
Description
Power supply or backup fault. Check
cable connection.
No fault.
Outputs are normal.
Outputs are faulted or disabled.
AC power is on.
AC power is off. Verify source power.
Base enclosure service procedures
59