4. Collect the oil and deliver it to the local collection service. Refit and tighten the drain and vent plugs
after draining.
Re-tighten the top connection of the oil cooler.
5. Remove the oil filter (OF). Clean the seat on the manifold. Oil the gasket of the new filter and screw
it into place. Tighten firmly by hand.
6. Remove filler plug (FC).
Fill the air receiver/oil tank (AR) with oil until the level reaches the filler neck.
Take care that no dirt drops into the system. Refit and tighten filler plug (FC).
7. Run the compressor loaded for a few minutes. Stop the compressor and wait a few minutes to allow
the oil to settle.
8. Depressurise the system by unscrewing filler plug (FC) just one turn to permit any pressure in the
system to escape. Remove the plug.
Add oil, the oil level should be between the top of the sight glass (Gl) and the filling point (FC).
Tighten the filler plug.
9. Reset the service warning after carrying out all service actions in the relevant Service Plan: see
Service
menu.
7.3

Oil separator change

Warning
Procedure
1. Run the compressor until warm. Stop the compressor, close the air outlet valve and switch off the
voltage. Wait a few minutes and depressurize by unscrewing oil filler plug (FC) just one turn to
permit any pressure in the system to escape.
2. Remove the cover (Ac) from the air receiver/oil tank (AR) by unscrewing the bolts.
2920 7101 51
The operator must apply all relevant
Oil drain plugs
Safety
precautions.
77