Chicago Pneumatic Compressors will decline any responsibility if these instructions are not respected. This equipment has been factory tested and satisfies normal operating conditions: they must not be exceeded as this would place the machine under abnormal stress and effort.
Page 3
WARNING: the operation connection cables between the different elements must never follow the same path as the existing power cords. A separate installation from the power cords must be carried out. • Install an RC filter on all the relay coils of the external operation units. 01/2008 Chicago Pneumatic Compressors Page 3 62 305 258 65...
E - Remote starting and stopping ..............................14 F - Rotation direction indicator - Phase controller ........................... 14 G - Centrifugal separator .................................. 15 Section 6 - Specific information for CPVS 40-50-60-75 ........................... 16 A - Description ....................................16 B - Safety ......................................16 C - Installation ....................................
- Safety devices: 1. A safety valve mounted on the oil reservoir. The Chicago Pneumatic Compressors CP model air compressor 2. An thermal protection device for the motor, situated in the is a compressed air unit and is presented as an entire unit starting box, to protect the motor from excessive overload.
E - Electronic board See the specific instructions for a description of the electronic plate, together with operating instructions : Notice N° 62 305 169 xx for version CPVS 01/2008 Chicago Pneumatic Compressors Page 7 62 305 258 65...
• The electric current must be cut whenever maintenance work is carried out on the machine (except for pressurized oil change) Fuses to be used for the isolating switch (RK5 type) CPVS Model 460 V 01/2008 Chicago Pneumatic Compressors Page 9 62 305 258 65...
"class B" and in presence of a live electrical conductor, it is recommended to use a CO2 extinguisher functioning by "smothering" (starvation of oxygen) while observing the user instructions applicable to the model. Fig. 3 01/2008 Chicago Pneumatic Compressors Page 10 62 305 258 65...
(rep. 49). The remaining oil, which is separated by the last stage of the oil separator, is drawn up by a dip tube and dispatched to the compressor. Fig. 4 - Air / oil circuit 01/2008 Chicago Pneumatic Compressors Page 11 62 305 258 65...
1 - Condensation intake 4 - Main duct 2 - Capacitive sensor 5 - Electric valve 3 - Receiver 6 - Membrane 3 - Technical features CPVS 40-50-60 71 in 11.2 in CPVS 75 71 in 13.6 in Maximum capacity of the compressor...
• Fast pollution of the oil thus an increase in oil change cycles. • Increased pollution of the air and oil filtering components that increases the deterioration of the mechanical components in the compressor, screw block, ... 01/2008 Chicago Pneumatic Compressors Page 13 62 305 258 65...
OF MENUS IN THE CONTROLLER, ACCESS 3 - Operation RESTRICTED TO TECHNICIANS CERTIFIED BY CHICAGO PNEUMATIC COMPRESSORS. In the event of a phase failure (detectable by this option) or an incorrect rotation direction, the trip switch sets off the machine's...
The condensates are evacuated from the separator through a trap with a solenoid drip valve or a trap with level detector if this option is installed. 01/2008 Chicago Pneumatic Compressors Page 15 62 305 258 65...
Section 6 - Specific information for CPVS 40-50-60-75 Refer also to the chapters concerning the standard machine. The inverter has a load circuit of thermally limited capacitors. Therefore, it is important to allow minimum 5 minutes between two successive power-ons. If this "CPVS"...
In this way, the pressure feedback loop is more stable to sudden is minimised (seenotice AIRLOGIC). changes in consumption (changes in the flow-rate). Do not set the stop pressure at a level beyond the machine's max P. 01/2008 Chicago Pneumatic Compressors Page 17 62 305 258 65...
Page 18
The pressure then rises again and the cycle starts over (fig. 14 d). To avoid pumping the system - frequent stop / start - drainage time may be increased (cf. notice AIRLOGIC). 01/2008 Chicago Pneumatic Compressors Page 18 62 305 258 65...
The main incidents likely to occur are listed below, along with the remedies to be applied. The keys to the control lamps relate to the instrument panel (refer to the AIRLOGIC Manual - E Section 1). 01/2008 Chicago Pneumatic Compressors Page 19 62 305 258 65...
• With an automatic drain, set the draining cycle accordingly and check that the drain is in good working condition. This recommendation is also fundamental in a circuit comprising an absorption dryer (risk of saturation of the alumina). 01/2008 Chicago Pneumatic Compressors Page 20 62 305 258 65...
• The machine can be restarted only after pressing the button C several times to return to STATE 0.1. Check the clamping of connections. • After restarting, check that there are no oil leaks. 01/2008 Chicago Pneumatic Compressors Page 21 62 305 258 65...
Disconnect from the compressed • Reassemble. air exit pipe from the air network. 5. Empty the circuits of oil and condensates. 6. Disconnect the compressor condensate piping from the condensate draining system. 01/2008 Chicago Pneumatic Compressors Page 22 62 305 258 65...
Remove retainer blocks. not removed. 9. THE COMPRESSOR STOPS a) Electromagnetic disturbance a) Add an interference suppression kit UNTIMELY OR CREATES on the Airlogic controller. (contact the after sales department) NON-EXISTING FAULTS 01/2008 Chicago Pneumatic Compressors Page 23 62 305 258 65...