22.0 CHANGING THE OIL (FIG. 27)
CAUTION: THIS OPERATION MUST BE DONE TOGETHER WITH THE OIL FILTER AND AIR FILTER EXCHANGE
BEFORE CARRYING OUT ANY MAINTENANCE JOBS IT IS OBLIGATORY TO STOP THE MACHINE AND
DISCONNECT IT FROM THE POWER MAINS AND FROM THE COMPRESSED AIR DISTRIBUTION
NETWORK.
Oil changing is an important operation for the compressor: if the lubrication of the bearings is not efficient, the compressor
life will be short.
The oil must be changed when the machine is still warm, that is immediately after stopping it.
The suggestions listed below should be scrupulously followed.
After draining the old oil out of the machine Ref. 1 Fig. 27.
- Fill the oil manifold Ref. 2 Fig. 27 up to the level mark
- Pour a drop of oil into the intake unit, as described in CHAP. 20.1
- Close all the protections (cover and front protection) Ref. 3 Fig. 27
- Start the compressor.
- After about 1 minute, stop the machine.
PROCEED AS DESCRIBED AT CHAPTER 15.3
3
2
THE OLD OIL MUST BE DISPOSED OF IN COMPLIANCE WITH THE REGULATIONS IN FORCE.
NOTE ON LUBRICANTS
When delivered the machine is filled with oil.
In normal conditions of use, these lubricants have proved to be able to withstand use for as many as 4.000 hours. However,
due to the external polluting agents that get into the compressor with the air that it takes in, it is advisable to change the oil at
more frequent intervals, as indicated on the routine maintenance chart.
If the compressor is being used at high temperatures (continuous operation above 90 °C) or in particularly severe conditions,
we advise changing the oil at shorter intervals than those recommended in the maintenance chart.
DO NOT TOP UP WITH DIFFERENT OILS
52 Code 9828093379 ed 00 05/2020
Oil
DO NOT EXCEED THE
MAXIMUM LEVEL.
MINIMUM LEVEL
WITH THE MACHINE
OFF
1
4
5
MAXIMUM LEVEL
WITH THE MACHINE
OFF
FIG. 27