Chapter 4 Storage Management; Raid Modes - Buffalo TS3210DN User Manual

Hide thumbs Also See for TS3210DN:
Table of Contents

Advertisement

Chapter 4 Storage Management

RAID Modes

TeraStations support many types of RAID. The type of RAID arrays available for use depends on how many drives are
installed in your TeraStation.
Notes:
• If you change the RAID mode, all data on the array is deleted. This is true for every procedure in this chapter.
Always back up any important data before performing actions that affect your RAID array.
• Drive capacity is displayed in Settings in actual gigabytes. The Properties window in Windows may show GiB
instead, which will be a smaller number.
• If the TeraStation is restarted or shut down while changing the RAID mode, the message that appears in Settings
or NAS Navigator2 will change from I46 or I47 to I18.
• RAID 5, 6, and 10 are only available for models with 4 drives.
RAID 6
RAID 6 arrays are available for TeraStations with 4 drives. RAID 6 combines 4 drives into a single array. The usable
space is equal to the sum of the capacity of all drives minus the capacity of two drives. For example, if 4 drives are
combined into a RAID 6 array, the usable space is the sum of the capacity of 2 drives. If 2 drives in the array are
damaged, you can recover data by replacing them. If 3 or more drives are damaged, your data is lost.
RAID 5
RAID 5 arrays are available for TeraStations with 3 or more drives. RAID 5 combines 3 or more drives into a single
array. The usable space is equal to the sum of the capacity of the drives minus the capacity of one drive. For
example, if 4 drives are combined into a RAID 5 array, the usable space is the sum of 3 drives. If one drive in the array
is damaged, you can recover data by replacing the damaged drive. If two or more drives are damaged at the same
time, your data is lost.
RAID 10
RAID 10 arrays are available for TeraStations with 4 drives. In this mode, mirrored pairs of drives in RAID 1 arrays
are combined into a RAID 0 array. The usable space is equal to the capacity of the smallest drive multiplied by the
number of drives divided by 2.
RAID 1
Combines 2 or more drives into a mirrored array. The available space in the array is the capacity of a single drive.
Identical data is written to each drive. If a drive is damaged, data can be recovered by replacing the damaged drive.
As long as one drive in the array remains undamaged, all data in the array can be recovered.
39