Code
I32
I33
I34
I37
I38
I40
I41
I42
I43
I44
I45
I46
I47
I48
I49
I50
I51
I52
Description
Displays after replacing the drive when the
RAID array needs to be rebuilt in Settings
or formatting is necessary.
An error occurred in replication, or
synchronization between the main
TeraStation and the backup TeraStation
failed during failover configuration.
A virus scan found a virus.
Settings initialization in progress.
Settings initialization is complete.
Beginning settings initialization. All data
on the drive 1 will be deleted.
Press the function button on the front to
start the settings initialization process.
Preparing to start the settings initialization
process.
The TeraStation was started from the
USB initialization device, but the settings
cannot be initialized from this USB
initialization device.
Initialization from the USB initialization
device was initiated, but drive 1 was not
detected.
Initialization failed.
Data migration or conversion (RAID
migration) is in progress.
This TeraStation is ready to become the
failover backup for the main TeraStation.
The main TeraStation in the failover
configuration cannot be found.
Failover maintenance is in progress.
Initializing the failover configuration.
A new firmware version has been released.
Corrective Action
From Settings, either rebuild the RAID
array or format the drive.
From Settings, navigate to Backup >
Replication and click Resync to execute
resynchronization.
If you configured the subfolders' access
restrictions to be inherited to the
replication or failover destinations, disable
them or change the destinations.
If the error is displayed again, contact
Buffalo technical support for assistance.
Once the virus is removed from the
quarantine folder, the message is no
longer displayed. If the antivirus software
is configured to delete viruses from the
quarantine folder automatically, then the
message will not be displayed.
-
-
-
-
-
-
Make sure that drive 1 is present and fully
inserted in its slot.
-
Do not turn off the TeraStation's power.
Press and hold the function button on the
front of the target TeraStation until it stops
beeping to accept failover backup status.
Make sure that the main TeraStation is on,
working, and connected to the network.
Do not turn off the TeraStation's power.
Do not turn off the TeraStation's power.
Update the firmware.