TROUBLESHOOTING

WARNING:
the machine.
FAULT
MACHINE DOES NOT
OPERATE
Make sure the electrical disconnect is OFF before working on
PROBABLE CAUSE
Machine is not plugged in to a
live circuit.
Bending leaf lifted before start
button is pressed.
Bending leaf micro-switch out of
adjustment.
Machine power switch is not lit.
The machine is hot and
overheated.
Bending leaf is raised before
starting machine.
Start pushbutton is faulty.
Loose connection
Clamp bar snaps down on the
release of the start button.
Blown fuses or tripped circuit
breakers.
REMEDY
Have qualified electrician check
circuit.
Return bending leaf to lower
position and press start button.
Adjust bending leaf micro-switch
to be pressed in when leaf is in
the released position.
Push switch to ON position and
make sure light is ON.
Let the machine cool and try to
start again.
Do Not lift the bending leaf prior
to starting the machine.
Try to start with the footswitch, if
it starts, replace the start switch.
Check the connector and
magnet at the electrical module
(Electrician Only)
Replace the 15 microfarad
capacitor.
Bridge rectifier may be blown.