NEC EXP801 Maintenance Manual page 158

Table of Contents

Advertisement

Chapter 3 Appendix
Microsoft-Windows-
DistributedCOM
10016
When running an OS for the first time
Microsoft-Windows-
WinRM
10149
When installing an OS
Application Event Log
Microsoft-Windows-WMI
24
At the time of applying Starter Pack
Microsoft-Windows-
Security-SPP
1014
When installing an OS
Microsoft-Windows-
Security-SPP
1015
When installing an OS
Microsoft-Windows-
Security-SPP
1058
When installing an OS
Microsoft-Windows-
User Profiles Service
1534
When installing an OS
158
In the settings of application-specific access authorization, access
authorization of local activation for COM server applications with CLSID
{D63B10C5-BB46-4990-A94F-E40B9D520160} and APPID
{9CA88EE3-ACB7-47C8-AFC4-AB702511C276} cannot be granted to
Error
the user NT AUTHORITY SYSTEM SID (S-1-5-18) whose address is
LocalHost (LRPC used) running with an SID unable to use application
containers (utilization disabled). This security access authorization can
be changed using the component service management tool.
If this is logged at the first boot of OS and the same event log is not
continuously logged, there is no problem.
Warning
The WinRM service is not listening for WS-Management requests.
If this event is logged together with ID 7036 "Service Control Manager
(Windows Remote Management (WS-Management) service has
stopped.), there is no problem in system operation.
Also, if WinRM event 10148 (WinRM service is listening
WS-Management requests.) is output immediately after this event, there
is no problem in system operation.
Event provider MLNXProvider attempted to register query "select * from
MLNX_NetAdapterStatusEvent" whose target class
"MLNX_NetAdapterStatusEvent" in //./root/standardcimv2/mlnx
Error
namespace does not exist. The query will be ignored.
* There may be cases that the above message is somewhat different.
This event is logged in the system when InfiniBand Adapter is
connected.
This event does not affect system operation.
Failed to obtain end-user license.
Error
hr=0x80072EE7
If this event is logged only when installing an OS and does not occur
repeatedly, there is no problem in system operation.
Detailed information of HRESULT
Warning
Returned hr=0xC004F022, original hr=0x80049E00
If this event is logged only when installing an OS and does not occur
repeatedly, there is no problem in system operation.
Failed to obtain certificate of purchase from ACPI table.
Error
Error code: 0xC004F057
This event does not affect system operation.
Profile notification of event Create for component
Warning
{2c86c843-77ae-4284-9722-27d65366543c} failed.
If this event is logged only when installing an OS and does not occur
repeatedly, there is no problem in system operation. Error code is not
implemented.
Express5800/R120g-1M, R120g-2M Maintenance Guide
2. List of Windows Event Logs

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express5800/r120g-2mExpress5800/r120g-1mExp802

Table of Contents